Delays in the detection of hypoxemia due to site of pulse oximetry probe placement

被引:29
作者
Hamber, EA [1 ]
Bailey, PL [1 ]
James, SW [1 ]
Wells, DT [1 ]
Lu, JK [1 ]
Pace, NL [1 ]
机构
[1] Univ Utah, Dept Anesthesiol, Salt Lake City, UT 84132 USA
关键词
hypoxemia; monitoring site; pulse oximetry;
D O I
10.1016/S0952-8180(99)00010-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objectives: To determine if there were anp differences in the time do detect hypoxemia related to the site of peripheral pulse oximetry (ear, hand and foot) during the rapid induction of hypoxemia in healthy volunteers. Design: Repeated-measures, longitudinal, observational study. Setting: Anesthesia clinical research area of the Department of Anesthesiology. Patients: 13 healthy volunteers, aged 18 to 44 years. Interventions: Nellcor N-200 (Nellcor, Inc., Pleasanton, CA) oximeter probes were placed at the ear, hand and foot. All units were turned on simultaneously with averaging times set for 5 seconds and signals sampled at 2 Hz. A computer-controlled anesthesia circuit was employed to induce mild hypercapnia and hyperoxia (end-tidal gas partial pressures: PETCO2 = 42 +/- 2 mmHg and PETO2 = 130 mmHg) for 5 minutes. PETO2 was then decreased to 45 +/- 2 mmHg over 60 seconds and held at that value for 5 minutes. Measurements and Main Results: The mean differences in time (sec) for pulse oximeters to detect hypoxemia (read less than 90%) between probe sites were determined and compared. The following mean differences in time (sec) for pulse oximeters to detect hypoxemia (read less than 90%) between probe sites were found: ear-hand = 6; hand-foot = 57; ear-foot = 63. Paired t-tests revealed statistically significant mean time delay differences of 51 seconds (p < 0.005) and 57 seconds (p < 0.005) for ear-hand versus hand-foot and for ear-hand versus ear-foot, respectively. Conclusions: In healthy volunteers, significant delays in the detection of acute hypoxemia by pulse oximetry occur when pulse oximeters are placed at the toe as compared with probes at either the ear or hand. (C) 1999 by Elsevier Science Inc.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 24 条
[1]   ADVERSE RESPIRATORY EVENTS IN ANESTHESIA - A CLOSED CLAIMS ANALYSIS [J].
CAPLAN, RA ;
POSNER, KL ;
WARD, RJ ;
CHENEY, FW .
ANESTHESIOLOGY, 1990, 72 (05) :828-833
[2]   DECREASED CIRCULATION TIME IN THE UPPER LIMB REDUCES THE LAG TIME OF THE FINGER PULSE OXIMETER RESPONSE [J].
DING, ZN ;
SHIBATA, K ;
YAMAMOTO, K ;
KOBAYASHI, T ;
MURAKAMI, S .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (01) :87-89
[3]   The hypoxic response: Huffing and HIFing [J].
Guillemin, K ;
Krasnow, MA .
CELL, 1997, 89 (01) :9-12
[4]   CIRCULATORY ADJUSTMENTS TO HYPOXIA [J].
HEISTAD, DD ;
ABBOUD, FM .
CIRCULATION, 1980, 61 (03) :463-470
[5]   Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery [J].
Iyer, P ;
McDougall, P ;
Loughnan, P ;
Mee, RBB ;
AlTawil, K ;
Carlin, J .
CRITICAL CARE MEDICINE, 1996, 24 (03) :507-511
[6]   EVALUATION OF THE OHMEDA 3700 PULSE OXIMETER - STEADY-STATE AND TRANSIENT-RESPONSE CHARACTERISTICS [J].
KAGLE, DM ;
ALEXANDER, CM ;
BERKO, RS ;
GIUFFRE, M ;
GROSS, JB .
ANESTHESIOLOGY, 1987, 66 (03) :376-380
[7]   PULSE OXIMETRY [J].
KELLEHER, JF .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (01) :37-62
[8]   COMPARISON OF 4 PULSE OXIMETERS - EFFECTS OF VENOUS OCCLUSION AND COLD-INDUCED PERIPHERAL VASOCONSTRICTION [J].
LANGTON, JA ;
LASSEY, D ;
HANNING, CD .
BRITISH JOURNAL OF ANAESTHESIA, 1990, 65 (02) :245-247
[9]   PULSE OXIMETRY - CLINICAL IMPLICATIONS AND RECENT TECHNICAL DEVELOPMENTS [J].
LINDBERG, LG ;
LENNMARKEN, C ;
VEGFORS, M .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 (03) :279-287
[10]  
MINEO R, 1993, REGION ANESTH, V18, P106