Preanalytical quality improvement: in quality we trust

被引:150
作者
Lippi, Giuseppe [1 ]
Becan-McBride, Kathleen [2 ]
Behulova, Darina [3 ]
Bowen, Raffick A. [4 ]
Church, Stephen [5 ]
Delanghe, Joris [6 ]
Grankvist, Kjell [7 ]
Kitchen, Steve [8 ]
Nybo, Mads [9 ]
Nauck, Matthias [10 ]
Nikolac, Nora [11 ]
Palicka, Vladimir [12 ,13 ]
Plebani, Mario [14 ]
Sandberg, Sverre [15 ]
Simundic, Ana-Maria [11 ]
机构
[1] Acad Hosp Parma, Clin Chem & Hematol Lab, Parma, Italy
[2] Univ Texas Hlth Sci Ctr, Dept Family & Community Med, Houston, TX USA
[3] Comenius Univ, Childrens Hosp, Dept Lab Med, Bratislava, Slovakia
[4] Stanford Univ, Med Ctr, Clin Chem & Immunol Lab, Dept Pathol, Stanford, CA 94305 USA
[5] BD Diagnost Preanalyt Syst, Oxford, England
[6] Ghent Univ Hosp, Dept Clin Chem, Ghent, Belgium
[7] Umea Univ, Dept Med Biosci, Umea, Sweden
[8] Royal Hallamshire Hosp, Sheffield Haemophilia & Thrombosis Ctr, Sheffield S10 2JF, S Yorkshire, England
[9] Odense Univ Hosp, Dept Clin Biochem & Pharmacol, DK-5000 Odense, Denmark
[10] Univ Med Greifswald, Inst Klin Chem & Lab Med, Greifswald, Germany
[11] Sestre Milosrdnice Univ Hosp, Univ Dept Chem, Zagreb, Croatia
[12] Charles Univ Prague, Univ Hosp, Hradec Kralove, Czech Republic
[13] Sch Med Hradec Kralove, Hradec Kralove, Czech Republic
[14] Univ Hosp, Dept Lab Med, Padua, Italy
[15] Haukeland Hosp, Lab Clin Biochem, N-5021 Bergen, Norway
关键词
errors; laboratory medicine; preanalytical phase; quality; standardization; PRIMARY-HEALTH-CARE; BLOOD COLLECTION TUBES; LABORATORY MEDICINE; HEMOLYSIS INDEX; CLINICAL LABORATORIES; PATIENT SAFETY; ISO; 15189; ERRORS; SAMPLE; DIAGNOSTICS;
D O I
10.1515/cclm-2012-0597
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Total quality in laboratory medicine should be defined as the guarantee that each activity throughout the total testing process is correctly performed, providing valuable medical decision-making and effective patient care. In the past decades, a 10-fold reduction in the analytical error rate has been achieved thanks to improvements in both reliability and standardization of analytical techniques, reagents, and instrumentation. Notable advances in information technology, quality control and quality assurance methods have also assured a valuable contribution for reducing diagnostic errors. Nevertheless, several lines of evidence still suggest that most errors in laboratory diagnostics fall outside the analytical phase, and the pre- and postanalytical steps have been found to be much more vulnerable. This collective paper, which is the logical continuum of the former already published in this journal 2 years ago, provides additional contribution to risk management in the preanalytical phase and is a synopsis of the lectures of the 2nd European Federation of Clinical Chemistry and Laboratory Medicine (EFLM)-Becton Dickinson (BD) European Conference on Preanalytical Phase meeting entitled "Preanalytical quality improvement: in quality we trust" (Zagreb, Croatia, 1-2 March 2013). The leading topics that will be discussed include quality indicators for preanalytical phase, phlebotomy practices for collection of blood gas analysis and pediatric samples, lipemia and blood collection tube interferences, preanalytical requirements of urinalysis, molecular biology hemostasis and platelet testing, as well as indications on best practices for safe blood collection. Auditing of the preanalytical phase by ISO assessors and external quality assessment for preanalytical phase are also discussed.
引用
收藏
页码:229 / 241
页数:13
相关论文
共 67 条
[1]   Minimum specimen volume requirements for routine coagulation testing - Dependence on citrate concentration [J].
Adcock, DM ;
Kressin, DC ;
Marlar, RA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 109 (05) :595-599
[2]  
[Anonymous], 2012, CONV BD MICR MAP MIC
[3]  
[Anonymous], 2012, BMC RES NOTES, DOI DOI 10.1186/1756-0500-5-39
[4]   Shop for quality or quantity ? Volumes and costs in clinical laboratories [J].
Barletta, Giovanni ;
Zaninotto, Martina ;
Faggian, Diego ;
Plebani, Mario .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (02) :295-301
[5]   RNA Extraction from Archival Formalin-Fixed Paraffin-Embedded Tissue: A Comparison of Manual, Semiautomated, and Fully Automated Purification Methods [J].
Bohmann, Kerstin ;
Hennig, Guido ;
Rogel, Uwe ;
Poremba, Christopher ;
Mueller, Berit Maria ;
Fritz, Peter ;
Stoerkel, Stephan ;
Schaefer, Karl-L. .
CLINICAL CHEMISTRY, 2009, 55 (09) :1719-1727
[6]   Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention [J].
Bolenius, Karin ;
Soderberg, Johan ;
Hultdin, Johan ;
Lindkvist, Marie ;
Brulin, Christine ;
Grankvist, Kjell .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (02) :303-310
[7]  
Bonini P, 2002, CLIN CHEM, V48, P691
[8]   Assay-specific differences in lipemic interference in native and intralipid-supplemented samples [J].
Bornhorst, JA ;
Roberts, RF ;
Roberts, WL .
CLINICAL CHEMISTRY, 2004, 50 (11) :2197-2201
[9]   Immunoassay interference by a commonly used blood collection tube additive, the organosilicone surfactant Silwet L-720 [J].
Bowen, RAR ;
Chan, Y ;
Ruddel, ME ;
Hortin, GL ;
Csako, G ;
Demosky, SJ ;
Remaley, AT .
CLINICAL CHEMISTRY, 2005, 51 (10) :1874-1882
[10]   Effect of blood collection tubes on total triiodothyronine and other laboratory assays [J].
Bowen, RAR ;
Chan, Y ;
Cohen, J ;
Rehak, NN ;
Hortin, GL ;
Csako, G ;
Remaley, AT .
CLINICAL CHEMISTRY, 2005, 51 (02) :424-433