Tracheal intubation through the laryngeal mask using a gum elastic bougie in the presence of cricoid pressure and manual in line stabilisation of the neck

被引:19
作者
Gabbott, DA [1 ]
Sasada, MP [1 ]
机构
[1] R ADAMS COWLEY SHOCK TRAUMA CTR,DIV ANESTHESIOL,BALTIMORE,MD 21201
关键词
equipment; laryngeal mask airways; intubation; trachea;
D O I
10.1111/j.1365-2044.1996.tb07754.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Forty adult patients had a gum elastic bougie passed blindly through a laryngeal mask on two occasions, after standard insertion, and after the application of cricoid pressure with manual in line stabilisation of the neck. After standard insertion the bougie entered the trachea on 11/40 occasions. With manual in line stabilisation of the neck and cricoid pressure applied, the bougie entered the trachea on 9/40 occasions. These results were not statistically significant. Blind passage of a gum elastic bougie through a laryngeal mask does not provide a reliable route into the trachea in either of the circumstances studied.
引用
收藏
页码:389 / 390
页数:2
相关论文
共 12 条
[1]   TRACHEAL PLACEMENT OF A GUM ELASTIC BOUGIE USING THE LARYNGEAL MASK AIRWAY [J].
ALLISON, A ;
MCCRORY, J .
ANAESTHESIA, 1990, 45 (05) :419-420
[2]  
[Anonymous], ANESTHESIOLOGY
[3]   CRICOID PRESSURE MAY PREVENT INSERTION OF THE LARYNGEAL MASK AIRWAY [J].
ANSERMINO, JM ;
BLOGG, CE .
BRITISH JOURNAL OF ANAESTHESIA, 1992, 69 (05) :465-467
[4]   CRICOID PRESSURE IMPEDES PLACEMENT OF THE LARYNGEAL MASK AIRWAY AND SUBSEQUENT TRACHEAL INTUBATION THROUGH THE MASK [J].
ASAI, T ;
BARCLAY, K ;
POWER, I ;
VAUGHAN, RS .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (01) :47-51
[5]  
BRIMACOMBE J, 1993, ANESTH ANALG, V77, P398
[6]  
CORK RC, 1994, ANESTH ANALG, V79, P719
[7]   EMERGENCY AIRWAY MANAGEMENT IN PATIENTS WITH CERVICAL-SPINE INJURIES [J].
CRISWELL, JC ;
PARR, MJA ;
NOLAN, JP .
ANAESTHESIA, 1994, 49 (10) :900-903
[8]   LARYNGEAL MASK AIRWAY INSERTION USING CRICOID PRESSURE AND MANUAL IN-LINE NECK STABILIZATION [J].
GABBOTT, DA ;
SASADA, MP .
ANAESTHESIA, 1995, 50 (08) :674-676
[9]   INTUBATION THROUGH THE LARYNGEAL MASK - A TECHNIQUE FOR UNEXPECTED DIFFICULT INTUBATION [J].
HEATH, ML ;
ALLAGAIN, J .
ANAESTHESIA, 1991, 46 (07) :545-548
[10]   AIRWAY PROTECTION BY THE LARYNGEAL MASK - A BARRIER TO DYE PLACED IN THE PHARYNX [J].
JOHN, RE ;
HILL, S ;
HUGHES, TJ .
ANAESTHESIA, 1991, 46 (05) :366-367