Comparison of methods for measuring albumin in peritoneal dialysis and hemodialysis patients

被引:33
作者
Joseph, R
Tria, L
Mossey, RT
Bellucci, AG
Mailloux, LU
Vernace, MA
Miller, I
Wilkes, BM
机构
[1] N SHORE UNIV HOSP,DIV NEPHROL & HYPERTENS,DEPT MED,MANHASSET,NY 11030
[2] N SHORE UNIV HOSP,DIV NEPHROL & HYPERTENS,DEPT LABS,MANHASSET,NY 11030
[3] CORNELL UNIV,COLL MED,MANHASSET,NY 11030
关键词
albumin methods; nephelometry; bromcresol green; bromcresol purple; continuous ambulatory peritoneal dialysis; hemodialysis;
D O I
10.1016/S0272-6386(96)90168-7
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Serum albumin levels have been used extensively as an indicator of morbidity in patients with end-stage renal disease. Recent evidence suggests that albumin levels vary considerably in hemodialysis patients depending on the laboratory method used, but formulas for comparing albumin values by different methods have not been developed, We prospectively evaluated the effects of measuring albumin by three different methods on paired plasma and serum from 23 patients on continuous ambulatory peritoneal dialysis (CAPD) and 53 patients on chronic maintenance hemodialysis. Plasma and serum gave virtually identical results independent of method used. In CAPD patients, bromcresol green and nephelometry gave nearly identical albumin measurements through the entire range of plasma levels. In contrast, bromcresol purple gave values that were 9.9% +/- 1.3% lower (P < 0.05). Hemodialysis patients showed a similar pattern with close agreement between bromcresol green and nephelometry, but bromcresol purple gave lower albumin levels by 19.1% +/- 1.2% (P < 0.05). The discrepancy in albumin in CAPD patients was significantly less than in the hemodialysis patients (P < 0.05), suggesting that there were fewer interfering substances in the blood of CAPD patients than in hemodialysis patients, Linear regression analysis was used to develop simple formulas for comparing albumin values obtained by the different methods in CAPD and hemodialysis patients. These studies show that values for albumin in blood vary significantly by method of analysis in CAPD and hemodialysis patients. By the use of these formulas, it becomes possible to compare albumin values between centers using different methods for the purpose of quality management. (C) 1996 by the National Kidney Foundation, Inc.
引用
收藏
页码:566 / 572
页数:7
相关论文
共 13 条
[1]  
[Anonymous], CLIN CHEM THEORY ANA
[2]   SERUM-ALBUMIN CONCENTRATION-RELATED HEALTH-CARE FINANCING ADMINISTRATION QUALITY ASSURANCE CRITERION IS METHOD-DEPENDENT - REVISION IS NECESSARY [J].
BLAGG, CR ;
LIEDTKE, RJ ;
BATJER, JD ;
RACOOSIN, B ;
SAWYER, TK ;
WICK, MJ ;
LAWSON, L ;
WILKENS, K .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (02) :138-144
[3]  
*DEP HLTH HUM SUBJ, 1994, OPP IMPR CAR AD CTR, P254
[4]   DEATH RISK IN HEMODIALYSIS-PATIENTS - THE PREDICTIVE VALUE OF COMMONLY MEASURED VARIABLES AND AN EVALUATION OF DEATH RATE DIFFERENCES BETWEEN FACILITIES [J].
LOWRIE, EG ;
LEW, NL .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 15 (05) :458-482
[5]   UNDERESTIMATION OF SERUM-ALBUMIN BY THE BROMCRESOL PURPLE METHOD AND A MAJOR ENDOGENOUS LIGAND IN UREMIA [J].
MABUCHI, H ;
NAKAHASHI, H .
CLINICA CHIMICA ACTA, 1987, 167 (01) :89-96
[6]   BROMCRESOL PURPLE METHOD FOR SERUM-ALBUMIN GIVES FALSELY LOW VALUES IN PATIENTS WITH RENAL-INSUFFICIENCY [J].
MAGUIRE, GA ;
PRICE, CP .
CLINICA CHIMICA ACTA, 1986, 155 (01) :83-88
[7]   THE UREA REDUCTION RATIO AND SERUM-ALBUMIN CONCENTRATION AS PREDICTORS OF MORTALITY IN PATIENTS UNDERGOING HEMODIALYSIS [J].
OWEN, WF ;
LEW, NL ;
LIU, Y ;
LOWRIE, EG ;
LAZARUS, JM .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) :1001-1006
[8]  
PINNELL AE, 1978, CLIN CHEM, V24, P80
[9]  
PODOLSKY DK, 1994, HARRISONS PRINCIPLE, P1448
[10]  
RODKEY FL, 1965, CLIN CHEM, V11, P478