Multicenter Evaluation of a Commercial Cytomegalovirus Quantitative Standard: Effects of Commutability on Interlaboratory Concordance

被引:27
作者
Hayden, R. T. [1 ]
Shahbazian, M. D. [2 ]
Valsamakis, A. [3 ]
Boonyaratanakornkit, J. [2 ]
Cook, L. [4 ,5 ]
Pang, X. L. [6 ,7 ]
Preiksaitis, J. K. [8 ]
Schoenbrunner, E. R. [2 ]
Caliendo, A. M. [9 ,10 ]
机构
[1] St Jude Childrens Res Hosp, Dept Pathol, Memphis, TN 38105 USA
[2] Life Technol, Carlsbad, CA USA
[3] Johns Hopkins Med, Dept Pathol, Baltimore, MD USA
[4] Univ Washington, Med Ctr, Dept Lab Med, Seattle, WA 98195 USA
[5] Fred Hutchinson Canc Res Ctr, Program Infect Dis, Seattle, WA 98104 USA
[6] Univ Alberta, Dept Lab Med & Pathol, Edmonton, AB, Canada
[7] Prov Lab Publ Hlth, Edmonton, AB, Canada
[8] Univ Alberta, Dept Med, Edmonton, AB, Canada
[9] Emory Univ, Sch Med, Dept Pathol & Lab Med, Atlanta, GA 30322 USA
[10] Emory Univ, Emory Ctr AIDS Res, Atlanta, GA 30322 USA
关键词
EPSTEIN-BARR-VIRUS; VIRAL LOAD ASSAYS; CLINICAL-CHEMISTRY; ACCURACY; SERUM;
D O I
10.1128/JCM.02036-13
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Commutability of quantitative reference materials has proven important for reliable and accurate results in clinical chemistry. As international reference standards and commercially produced calibration material have become available to address the variability of viral load assays, the degree to which such materials are commutable and the effect of commutability on assay concordance have been questioned. To investigate this, 60 archived clinical plasma samples, which previously tested positive for cytomegalovirus (CMV), were retested by five different laboratories, each using a different quantitative CMV PCR assay. Results from each laboratory were calibrated both with lab-specific quantitative CMV standards ("lab standards") and with common, commercially available standards ("CMV panel"). Pairwise analyses among laboratories were performed using mean results from each clinical sample, calibrated first with lab standards and then with the CMV panel. Commutability of the CMV panel was determined based on difference plots for each laboratory pair showing plotted values of standards that were within the 95% prediction intervals for the clinical specimens. Commutability was demonstrated for 6 of 10 laboratory pairs using the CMV panel. In half of these pairs, use of the CMV panel improved quantitative agreement compared to use of lab standards. Two of four laboratory pairs for which the CMV panel was noncommutable showed reduced quantitative agreement when that panel was used as a common calibrator. Commutability of calibration material varies across different quantitative PCR methods. Use of a common, commutable quantitative standard can improve agreement across different assays; use of a noncommutable calibrator can reduce agreement among laboratories.
引用
收藏
页码:3811 / 3817
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 2009, 151942009 ISO
[2]  
[Anonymous], 2010, Collaborative study to evaluate the proposed 1st [first] WHO international standard for human cytomegalovirus (HCMV) for nucleic acid amplification (NAT)- based assays
[3]   A Commutable Cytomegalovirus Calibrator Is Required to Improve the Agreement of Viral Load Values between Laboratories [J].
Caliendo, Angela M. ;
Shahbazian, Mona D. ;
Schaper, Carl ;
Ingersoll, Jessica ;
Abdul-Ali, Deborah ;
Boonyaratanakornkit, Jerry ;
Pang, Xiao-Li ;
Fox, Julie ;
Preiksaitis, Jutta ;
Schoenbrunner, E. Ralf .
CLINICAL CHEMISTRY, 2009, 55 (09) :1701-1710
[4]  
Cattozzo G, 2001, CLIN CHEM, V47, P2108
[5]   Myoglobin and creatine kinase isoenzyme MB mass assays: intermethod behaviour of patient sera and commercially available control materials [J].
Cattozzo, G ;
Franzini, C ;
d'Eril, GVM .
CLINICA CHIMICA ACTA, 2001, 303 (1-2) :55-60
[6]  
ECKFELDT JH, 1993, ARCH PATHOL LAB MED, V117, P381
[7]  
FASCE CF, 1973, CLIN CHEM, V19, P5
[8]   Impact of reference materials on accuracy in clinical chemistry [J].
Franzini, C ;
Ceriotti, F .
CLINICAL BIOCHEMISTRY, 1998, 31 (06) :449-457
[9]  
Hayden RT, 2008, J CLIN MICROBIOL, V46, P157, DOI 10.1128/JCM.01252-07
[10]   Factors Contributing to Variability of Quantitative Viral PCR Results in Proficiency Testing Samples: a Multivariate Analysis [J].
Hayden, R. T. ;
Yan, X. ;
Wick, M. T. ;
Rodriguez, A. B. ;
Xiong, X. ;
Ginocchio, C. C. ;
Mitchell, M. J. ;
Caliendo, A. M. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (02) :337-345