Outbreak of severe Pseudomonas aeruginosa respiratory infections due to contaminated nebulizers

被引:59
作者
Cobben, NAM
Drent, M
Jonkers, M
Wouters, EFM
Vaneechoutte, M
Stobberingh, EE
机构
[1] UNIV LIMBURG HOSP,DEPT PULM,6200 AZ MAASTRICHT,NETHERLANDS
[2] UNIV LIMBURG HOSP,DEPT MED MICROBIOL,6200 AZ MAASTRICHT,NETHERLANDS
[3] STATE UNIV GHENT HOSP,DEPT CLIN BIOL IMMUNOL & MICROBIOL,GHENT,BELGIUM
关键词
Pseudomonas aeruginosa; contamination of nebulizers; hospital acquired pneumonia;
D O I
10.1016/S0195-6701(96)90030-4
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
During the six months from January-June 1994, 10 cases of severe and 11 of less severe pulmonary infection caused by Pseudomonas aeruginosa were diagnosed in patients with chronic obstructive airways disease. Possible sources were evaluated. P. aeruginosa was isolated from four of the 22 nebulizers tested. The relationship of isolates from the patients and nebulizers was confirmed by sero- and phage-typing, and by arbitrarily-primed polymerase chain reaction (AP-PCR). Three types were identified and the distribution of types in patients with severe infection was as follows (one patient had a multiple infection). Type I was isolated from two nebulizers and from sputa, and/or blood and/or bronchial protected specimen brush samples or bronchial lavage fluid from four patients. Type II came from the sputa of three patients and a third nebulizer; and type III from sputa and/or blood of four further patients and another nebulizer. The data provided evidence for the relation between P. aeruginosa as a cause of infection and the contamination of the nebulizers. When nebulizer mouthpieces were changed every 24h and sterilized between patients, no more contamination occurred, and the outbreak ceased.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 21 条
[1]  
BRANDLI O, 1994, EUR RESPIR REV, V18, P102
[2]  
CHRISTOPHER KL, 1983, AM REV RESPIR DIS, V128, P271
[3]  
CROSS A, 1983, REV NFECT DIS, V585, pS837
[4]   COMPARATIVE EFFICACY OF ALTERNATIVE HAND-WASHING AGENTS IN REDUCING NOSOCOMIAL INFECTIONS IN INTENSIVE-CARE UNITS [J].
DOEBBELING, BN ;
STANLEY, GL ;
SHEETZ, CT ;
PFALLER, MA ;
HOUSTON, AK ;
ANNIS, L ;
LI, N ;
WENZEL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (02) :88-93
[5]   NEBULIZATION EQUIPMENT - A POTENTIAL SOURCE OF INFECTION IN GRAM-NEGATIVE PNEUMONIAS [J].
EDMONDSON, EB ;
REINARZ, JA ;
PIERCE, AK ;
SANFORD, JP .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1966, 111 (04) :357-+
[6]   PSEUDOMONAS-AERUGINOSA SEROTYPE O-12 OUTBREAK STUDIED BY ARBITRARY PRIMER PCR [J].
ELAICHOUNI, A ;
VERSCHRAEGEN, G ;
CLAEYS, G ;
DEVLEESCHOUWER, M ;
GODARD, C ;
VANEECHOUTTE, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (03) :666-671
[7]   MICROORGANISMS IN INHALATION EQUIPMENT USED AT HOME [J].
EXNER, M ;
VOGEL, F ;
ROST, HD .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1983, 108 (01) :12-17
[8]   PSEUDOMONAS-AERUGINOSA - GROWTH IN DISTILLED WATER FROM HOSPITALS [J].
FAVERO, MS ;
CARSON, LA ;
BOND, WW ;
PETERSEN, NJ .
SCIENCE, 1971, 173 (3999) :836-&
[9]   FINE-PARTICLE HUMIDIFIERS - SOURCE OF PSEUDONOMONAS-AERUGINOSA INFECTIONS IN A RESPIRATORY-DISEASE UNIT [J].
GRIEBLE, HG ;
COLTON, FR ;
BIRD, TJ ;
TOIGO, A ;
GRIFFITH, LG .
NEW ENGLAND JOURNAL OF MEDICINE, 1970, 282 (10) :531-&
[10]   OUTBREAK OF INFECTION IN A BURNS UNIT DUE TO PSEUDOMONAS-AERUGINOSA ORIGINATING FROM CONTAMINATED TUBING USED FOR IRRIGATION OF PATIENTS [J].
KOLMOS, HJ ;
THUESEN, B ;
NIELSEN, SV ;
LOHMANN, M ;
KRISTOFFERSEN, K ;
ROSDAHL, VT .
JOURNAL OF HOSPITAL INFECTION, 1993, 24 (01) :11-21