Solid-phase spectrophotometric determination of trace amounts of hydrazine at sub-ng ml(-1) level

被引:70
作者
OrtegaBarrales, P
MolinaDiaz, A
PascualReguera, MI
CapitanVallvey, LF
机构
[1] UNIV JAEN,FAC EXPT SCI,DEPT PHYS & ANALYT CHEM,JAEN,SPAIN
[2] UNIV GRANADA,FAC SCI,DEPT ANALYT CHEM,E-18071 GRANADA,SPAIN
关键词
solid phase spectrophotometry; hydrazine; boiler feed and natural waters; urine; isoniazid;
D O I
10.1016/S0003-2670(97)00386-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very sensitive method for the determination of trace amounts of hydrazine by Solid-phase spectrophotometry has been developed. The method is based on the fixation of an aldazine derivative of hydrazine on a cation-exchange resin and the resin phase absorbance being measured directly. It allows the determination of hydrazine in the range 0.08-1.20 ng ml(-1) (with a RSD of 3.4% and an apparent molar absorptivity of 2.7 x 10(8) l mol(-1) cm(-1)). The method was applied to the determination of hydrazine in boiler feed and natural water samples, urine and isoniazid tablets. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:115 / 122
页数:8
相关论文
共 25 条
[1]  
ADBON HM, 1977, ANAL CHIM ACTA, V93, P221
[2]   SPECTROPHOTOMETRIC DETERMINATION OF TRACE AMOUNTS OF HYDRAZINE IN POLLUTED WATER [J].
AMLATHE, S ;
GUPTA, VK .
ANALYST, 1988, 113 (09) :1481-1483
[3]   SOME OBSERVATIONS ON A FIELD PROCEDURE FOR SAMPLING AND DETERMINATION OF LOW CONCENTRATIONS OF HYDRAZINE IN AIR [J].
AMLATHE, S ;
GUPTA, VK .
MICROCHEMICAL JOURNAL, 1990, 42 (03) :331-335
[4]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[5]   SPECTROPHOTOMETRIC DETERMINATION OF HYDRAZINE AND I,I-DIMETHYLHYDRAZINE SEPARATELY OR IN ADMIXTURE [J].
BAILEY, LC ;
MEDWICK, T .
ANALYTICA CHIMICA ACTA, 1966, 35 (03) :330-&
[6]   FLOW-INJECTION ANALYSIS FOR POWER-PLANTS - EVALUATION OF DETECTORS FOR THE DETERMINATION OF CONTROL PARAMETERS IN CONDITIONED WATER STEAM CYCLES [J].
BALCONI, ML ;
SIGON, F ;
BORGARELLO, M ;
FERRAROLI, R ;
REALINI, F .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :167-173
[7]   LOW-LEVEL DETERMINATION OF HYDRAZINE IN BOILER FEED WATER WITH AN UNSEGMENTED HIGH-SPEED CONTINUOUS-FLOW SYSTEM [J].
BASSON, WD ;
VANSTADEN, JF .
ANALYST, 1978, 103 (1230) :998-1001
[8]  
DECORDOVA MLF, 1995, TALANTA, V43, P1057
[9]  
DESANTOS SAD, 1992, STANDARD METHODS EXA
[10]  
FOGG AG, 1984, ANALYST, V109, P901, DOI 10.1039/an9840900901