Detectability of pulmonary perfusion defect and influence of breath holding on contrast-enhanced thick-slice 2D and on 3D MR pulmonary perfusion images

被引:21
作者
Matsuoka, S [1 ]
Uchiyama, K [1 ]
Shima, H [1 ]
Terakoshi, H [1 ]
Nojiri, Y [1 ]
Oishi, S [1 ]
Ogata, H [1 ]
机构
[1] Teikyo Univ, Ichihara Hosp, Sch Med, Dept Radiol, Chiba 2990111, Japan
关键词
lung; magnetic resonance; perfusion; scintigraphy; breath-hold;
D O I
10.1002/jmri.1222
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The present study assesses the detectability of perfusion defect and the influence of breathhold on pulmonary magnetic resonance (MR) perfusion imaging using contrast-enhanced thick-slice two-dimensional (2D) fast gradient-echo sequence compared with three-dimensional (3D) fast spoiled gradient-recalled sequence. Dynamic studies were performed in 16 patients. MR perfusion images were interpreted by two independent observers using perfusion scintigraphy as the reference standard. The patients were divided into two groups according to the duration of holding the breath measured during MR imaging. The sensitivity and specificity of 2D MR perfusion imaging in detecting perfusion defects were 93% and 94%, respectively, while those of 3D MR perfusion imaging were 89% and 85%, respectively. The diagnostic accuracy of 2D MR perfusion imaging was significantly higher than that of 3D MR perfusion imaging (P < 0.05) among those who could not hold their breath. Therefore, 2D MR perfusion imaging offers promise for evaluating pulmonary perfusion even among patients who cannot hold their breath. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:580 / 585
页数:6
相关论文
共 22 条
[1]  
Amundsen T, 2000, J Magn Reson Imaging, V12, P224, DOI 10.1002/1522-2586(200008)12:2<224::AID-JMRI3>3.0.CO
[2]  
2-E
[3]   Pulmonary embolism: Detection with MR perfusion imaging of lung - A feasibility study [J].
Amundsen, T ;
Kvaerness, J ;
Jones, RA ;
Waage, A ;
Bjermer, L ;
Nilsen, G ;
Haraldseth, O .
RADIOLOGY, 1997, 203 (01) :181-185
[4]   Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging - Application to unilateral lung transplantation [J].
Berthezene, Y ;
Croisille, P ;
Bertocchi, M ;
Houzard, C ;
Bendib, K ;
Revel, D .
INVESTIGATIVE RADIOLOGY, 1997, 32 (06) :351-356
[5]  
Berthezène Y, 1999, J MAGN RESON IMAGING, V9, P61, DOI 10.1002/(SICI)1522-2586(199901)9:1<61::AID-JMRI8>3.0.CO
[6]  
2-Z
[7]   Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging [J].
Edelman, RR ;
Hatabu, H ;
Tadamura, E ;
Li, W ;
Prasad, PV .
NATURE MEDICINE, 1996, 2 (11) :1236-1239
[8]   Pulmonary perfusion and angiography: Evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE [J].
Hatabu, H ;
Gaa, J ;
Kim, D ;
Li, W ;
Prasad, PV ;
Edelman, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) :653-655
[9]   Pulmonary perfusion: Qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH [J].
Hatabu, H ;
Gaa, J ;
Kim, D ;
Li, W ;
Prasad, PV ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :503-508
[10]   Time-resolved projection angiography after bolus injection of contrast agent [J].
Hennig, J ;
Scheffler, K ;
Laubenberger, J ;
Strecker, R .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :341-345