Quantitative coupling of supercritical fluid extraction and high-performance liquid chromatography by means of a coated open-tubular interface

被引:13
作者
Stone, MA [1 ]
Taylor, LT [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Dept Chem, Blacksburg, VA 24061 USA
关键词
supercritical fluid extraction; interfaces; SFE-HPLC; instrumentation;
D O I
10.1016/S0021-9673(01)01208-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Supercritical fluid extraction was coupled on-line with reversed-phase high-performance liquid chromatography (HPLC). An open-tubular column with a 95% methyl-5% phenyl stationary phase was utilized as an interface between the two systems. This phase allowed for good analyte focusing onto the packed analytical column and exhibited low reactivity. Due to the non-polar nature of this phase there was a low tendency for analytes. to be prematurely rinsed off the interface by condensed modifier. Using this approach, it was possible to transfer the extracted analytes quantitatively to the HPLC column in the presence of as much as 10% (v/v) methanol. By placing a 10 in guard column at the head of the interface, the same could be accomplished with ethanol as the modifier: allowing the extraction to be conducted entirely with non-toxic fluids. The method also allowed the use of very practical extraction parameters in terms of amount extracted, extraction flow-rate, extraction vessel volume, and extraction time. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:53 / 65
页数:13
相关论文
共 13 条
[1]  
ASHRAFKHORASSANI M, 1995, HRC-J HIGH RES CHROM, V18, P472
[2]   MEMBRANE INTERFACE FOR ONLINE SUPERCRITICAL-FLUID EXTRACTION FLOW-INJECTION ANALYSIS [J].
BREWSTER, JD ;
MAXWELL, RJ ;
HAMPSON, JW .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2137-2140
[3]  
Burford MD, 1997, ADV CHROMATOGR, V37, P163
[4]   ONLINE COUPLING OF SUPERCRITICAL FLUID EXTRACTION WITH MULTIDIMENSIONAL MICROCOLUMN LIQUID-CHROMATOGRAPHY GAS-CHROMATOGRAPHY [J].
CORTES, HJ ;
GREEN, LS ;
CAMPBELL, RM .
ANALYTICAL CHEMISTRY, 1991, 63 (23) :2719-2724
[5]  
ISCHI F, 1995, CHROMATOGRAPHIA, V41, P238
[6]   DETERMINATION OF PLANAR PCBS BY COMBINING ONLINE SFE-HPLC AND GC-ECD OR GC/MS [J].
JOHANSEN, HR ;
BECHER, G ;
GREIBROKK, T .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :4068-4073
[7]   TANDEM SUPERCRITICAL-FLUID EXTRACTION AND LIQUID-CHROMATOGRAPHY SYSTEM FOR DETERMINATION OF CHLORINATED PHENOLS IN SOLID MATRICES [J].
LIU, MH ;
KAPILA, S ;
NAM, KS .
JOURNAL OF CHROMATOGRAPHY, 1993, 639 (02) :151-157
[8]  
MOUGIN C, 1996, J HIGH RES CHROMATOG, V19, P700
[9]   SFE-GC with quantitative transfer of the extraction effluent to a megabore capillary column (vol 72, pg 3085, 2000) [J].
Stone, MA ;
Taylor, LT .
ANALYTICAL CHEMISTRY, 2000, 72 (18) :4529-4529
[10]   SFE-GC with quantitative transfer of the extraction effluent to a megabore capillary column [J].
Stone, MA ;
Taylor, LT .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3085-3092