Dry Drops:: a new preservative-free drug delivery system

被引:16
作者
Diestelhorst, M
Grunthal, S
Süverkrüp, R
机构
[1] Univ Cologne, Dept Ophthalmol, D-50931 Cologne, Germany
[2] Univ Bonn, Dept Pharmaceut Technol, D-5300 Bonn, Germany
关键词
Visual Analogue Scale; Active Ingredient; Drug Delivery System; Good Tolerability; Application Device;
D O I
10.1007/s004170050250
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We compared the tolerability and safety of a lyophilisate (Dry Drops) with conventional eye drops containing the same polymer and electrolytes. In Dry Drops the active ingredient is incorporated in a drop of hydrophilic polymer solution freeze-dried on the tip of a soft hydrophobic carrier strip. Upon contact with tear film and/or conjunctiva the lyophilisate immediately rehydrates and detaches from the carrier. a Methods: Dry Drops containing HPMC as active ingredient and a preservative-free tear film substitute were applied to 64 eyes of 32 healthy volunteers according to a 2(2) factorial design in an open-label, cross-over, randomised study. Tolerability and safety were quantified and qualified at 0.5, 2, 5 and 10 min after administration via slit-lamp biomicroscopy, questionnaire and visual analogue scales. Results: The differences between Dry Drops and conventional eye drops were not statistically significant. The initial sensation of Dry Drops was slightly less uncomfortable than that of the conventional ophthalmic solution. None of the eyes showed any clinical findings with safety implications. a Conclusion: The safety and tolerability of a new application form were demonstrated in this phase I study. The improved chemical stability, exact dosing, reduced risk of lesions re, the eye surface and good tolerability suggest that the new application device has promise for treatment in ophthalmology as well as in other medical subspecialties.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 15 条
[1]   THE OPHTHALMIC ROD - A NEW OPHTHALMIC DRUG DELIVERY SYSTEM .1. [J].
ALANI, SD .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1990, 228 (04) :297-301
[2]  
Brewitt H, 1982, Fortschr Ophthalmol, V79, P118
[3]  
BROWN MM, 1984, CAN J OPHTHALMOL, V19, P1
[4]   CORNEAL CYTO-TOXICITY OF TOPICALLY APPLIED DRUGS, VEHICLES AND PRESERVATIVES [J].
BURSTEIN, NL .
SURVEY OF OPHTHALMOLOGY, 1980, 25 (01) :15-30
[5]  
DESANTIS LM, 1994, OCULAR PHARM, P22
[6]   THE OCULAR TOLERABILITY OF A NEW OPHTHALMIC DRUG-DELIVERY SYSTEM (NODS) [J].
DIESTELHORST, M ;
KRIEGLSTEIN, GK .
INTERNATIONAL OPHTHALMOLOGY, 1994, 18 (01) :1-4
[7]  
DIESTELHORST M, 1990, Z PRAKT AUGENHEILKD, V11, P230
[8]  
FRAUNFELDER FT, 1996, DRUG INDUCED OCULAR, P420
[9]   CYTOTOXICITY OF OPHTHALMIC PRESERVATIVES [J].
GASSET, AR ;
ISHII, Y ;
KAUFMAN, HE ;
MILLER, T .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1974, 78 (01) :98-105
[10]  
HAVENER WH, 1994, OCULAR PHARM, P1