Levels of naturally occurring microorganisms on surgical instruments after clinical use and after washing

被引:37
作者
Chu, NS [1 ]
Chan-Myers, H [1 ]
Ghazanfari, N [1 ]
Antonoplos, P [1 ]
机构
[1] Adv Sterilizat Prod, Irvine, CA 92618 USA
关键词
D O I
10.1016/S0196-6553(99)70050-7
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Surgical instruments exposed to sterile body sites should be contaminated with relatively low levels of microbial contamination or bioburden; however, few studies in the literature have determined the quantitative level and types of contamination. A study was conducted at 2 clinical sites to determine the level of microbial contamination of surgical instruments after clinical use and after washing. Quantitative assays showed that bioburden levels were in the range of 0 to 4415 colony forming units per instrument after clinical use, and 88% of the instruments had bioburden levels lower than 1000. As expected, a reduction in counts occurred after washing; however, in some cases, higher counts were found on the instruments after the washing process. Although the washing procedure is effective in reducing the microbial levels deposited on the surgical instruments during use, a recontamination process occurs that results in increased counts after washing. The low bioburden level after washing consists of predominantly vegetative microorganisms that present a relatively low challenge to sterilization and disinfection systems.
引用
收藏
页码:315 / 319
页数:5
相关论文
共 9 条
[1]   IN-HOSPITAL EVALUATION OF ORTHOPHTHALALDEHYDE AS A HIGH-LEVEL DISINFECTANT FOR FLEXIBLE ENDOSCOPES [J].
ALFA, MJ ;
SITTER, DL .
JOURNAL OF HOSPITAL INFECTION, 1994, 26 (01) :15-26
[2]  
*ASS ADV MED INSTR, 1995, 81991 TIR ASS ADV 1, P735
[3]   Natural bioburden levels detected on rigid lumened medical devices before and after cleaning [J].
Chan-Meyers, H ;
McAlister, D ;
Antonoplos, P .
AMERICAN JOURNAL OF INFECTION CONTROL, 1997, 25 (06) :471-476
[4]   Natural bioburden levels detected on flexible gastrointestinal endoscopes after clinical use and manual cleaning [J].
Chu, NS ;
McAlister, D ;
Antonoplos, PA .
GASTROINTESTINAL ENDOSCOPY, 1998, 48 (02) :137-142
[5]  
Nystrom B, 1981, J Hosp Infect, V2, P363, DOI 10.1016/0195-6701(81)90069-4
[6]   APIC guideline for selection and use of disinfectants [J].
Rutala, WA .
AMERICAN JOURNAL OF INFECTION CONTROL, 1996, 24 (04) :313-342
[7]  
RUTALA WA, 1997, AJIC AM J INFECT CON, V25, P185
[8]  
VAVERO MS, 1991, DISINFECTION STERILI, P617
[9]  
1994, STATISTICA, V1, P1438