TIPS placement in swine, guided by electromagnetic real-time needle tip localization displayed on previously acquired 3-D CT

被引:31
作者
Solomon, SB [1 ]
Magee, C [1 ]
Acker, DE [1 ]
Venbrux, AC [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Div Cardiovasc & Intervent Radiol, Baltimore, MD 21287 USA
关键词
shunts portosystemic; TIPS; computed tomography guidance; computed tomography; 3-dimensional; stereotaxis;
D O I
10.1007/s002709900416
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Purpose: To determine the feasibility of guiding a transjugular intrahepatic portosystemic shunt (TIPS) procedure with an electromagnetic real-time needle tip position sensor coupled to previously acquired 3-dimensional (3-D) computed tomography (CT) images. Methods: An electromagnetic position sensor was placed at the tip of a Colapinto needle. The real-time position and orientation of the needle tip was then displayed on previously acquired 3-D CT images which were registered with the five swine. Portal vein puncture was then attempted in all animals. Results: The computer calculated accuracy of the position sensor was on average 3 mm. Four of five portal vein punctures were successful. In the successes, only one or two attempts were necessary and success was achieved in minutes. Conclusion: A real-time position sensor attached to the tip of a Colapinto needle and coupled to previously acquired 3-D CT images may potentially aid in entering the portal vein during the TIPS procedure.
引用
收藏
页码:411 / 414
页数:4
相关论文
共 14 条
[1]
Extrahepatic portal vein puncture and intra-abdominal hemorrhage during transjugular intrahepatic portosystemic shunt creation [J].
Davis, AG ;
Haskal, ZJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (06) :863-866
[2]
Use of CT-guided marking of the portal vein in creation of 150 transjugular intrahepatic portosystemic shunts [J].
Fontaine, AB ;
Verschyl, A ;
Hoffer, E ;
Borsa, J ;
Dowd, M .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (06) :1073-1077
[3]
COMPLICATIONS OF TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT - A COMPREHENSIVE REVIEW [J].
FREEDMAN, AM ;
SANYAL, AJ ;
TISNADO, J ;
COLE, PE ;
SHIFFMAN, ML ;
LUKETIC, VA ;
PURDUM, PP ;
DARCY, MD ;
POSNER, MP .
RADIOGRAPHICS, 1993, 13 (06) :1185-1210
[4]
Gepstein L, 1997, CIRCULATION, V95, P1611
[5]
CO2 fine-needle TIPS [J].
Hawkins, IF ;
Johnson, AW ;
Caridi, JG ;
Weingarten, KE .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (02) :235-239
[6]
CT-GUIDED LOCALIZATION OF THE PORTAL-VEIN BEFORE CREATION OF A TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT [J].
KHABIRI, H ;
FONTAINE, A ;
STOCKUM, A ;
SPIGOS, DG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :746-747
[7]
Radiodermatitis after transjugular intrahepatic portosystemic shunt [J].
Knautz, MA ;
Abele, DC ;
Reynolds, TL .
SOUTHERN MEDICAL JOURNAL, 1997, 90 (03) :352-356
[8]
Creation of a portal vein to inferior vena cava shunt using CT guidance and a covered endovascular stent [J].
Quinn, SF ;
Sheley, RC ;
Semonsen, KG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) :1159-1160
[9]
The transjugular intrahepatic portosystemic stent shunt: A review of the literature and own experiences [J].
Rossle, M ;
Haag, K ;
Blum, H .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1996, 11 (03) :293-298
[10]
Technical aspects of accessing the portal vein during the TIPS procedure [J].
Saxon, RR ;
Keller, FS .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (05) :733-744