Revision of a cemented acetabular component to a cementless acetabular component - A ten to fourteen-year follow-up study

被引:76
作者
Templeton, JE [1 ]
Callaghan, JJ
Goetz, DD
Sullivan, PM
Johnston, RC
机构
[1] Univ Iowa, Coll Med, Iowa City, IA 52242 USA
[2] Iowa Methodist Med Ctr, Des Moines, IA USA
关键词
D O I
10.2106/00004623-200111000-00014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although cementless acetabular components are routinely used in revision hip surgery, few investigators have evaluated the retention and efficacy of these components in the long term. In the current study, the clinical and radiographic outcomes of a series of arthroplasties performed by one surgeon with a cementless acetabular component were assessed at a minimum of ten years. Methods: From 1986 through 1988, sixty-one consecutive revision total hip arthroplasties were performed in fifty-five patients because of aseptic failure of one or both components of a prosthesis in which both components had been cemented. Twenty-eight patients (thirty-two hips) were alive at a mean of 12.9 years (range, 11.5 to 14.3 years) after the operation. In all of the patients, the acetabular component was revised to a porous-coated Harris-Galante component inserted without cement, and the femoral component was revised to an Iowa component affixed with contemporary cementing techniques. The hips were evaluated clinically and radiographically at a minimum of ten years subsequent to the index revision. No hips were lost to follow-up. Results: None of the acetabular components required revision because of aseptic loosening. Two hips (3%) demonstrated radiographic evidence of aseptic loosening of the acetabular component. The polyethylene liner was exchanged during the follow-up period in eight hips. Conclusion: After a minimum of ten years of follow-up, cementless acetabular fixation in revision hip arthroplasty had produced durable results that were markedly better than those reported for acetabular fixation with cement.
引用
收藏
页码:1706 / 1711
页数:6
相关论文
共 29 条
[1]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]   IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[3]  
BERGER RA, 1996, CLIN ORTHOP RELAT R, V333, P134
[4]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[5]  
CHAREANCHOLVANI.K, 1999, CLIN ORTHOP RELAT R, V361, P140
[6]   Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) :247-255
[7]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, V243, P126
[8]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[9]  
ESTOCK DM, 1994, CLIN ORTHOP RELAT R, P190
[10]   Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft - Study with a minimum five-year follow-up [J].
Garbuz, D ;
Morsi, E ;
Gross, AE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (05) :693-697