Analysis of the dose-surface histogram and dose-wall histogram for the rectum and bladder

被引:49
作者
Li, SD
Boyer, A
Lu, Y
Chen, GTY
机构
[1] STANFORD UNIV,DEPT RADIAT ONCOL,STANFORD,CA 94305
[2] UNIV CHICAGO,DEPT RADIAT & CELLULAR ONCOL,CHICAGO,IL 60637
关键词
dose-wall histogram; dose-surface histogram; error analysis;
D O I
10.1118/1.598014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dose distribution throughout a hollow organ is represented by either a dose-surface histogram (DSH) or a dose-wall histogram (DWH). A spherical shell model for the bladder and a cylindrical shell model for the rectum were introduced for quantifying the difference between the DWH and DSH. The difference was given by subtraction of the percent volume of the wall from the percent area of the surface for any specific dose level. Taking the dose-grid size and contour-delineation uncertainties into account, the DSH and DWH calculation errors were estimated by simplified formulas. The DSHs and DWHs for the rectum and bladder in patients undergoing four-field-prostate treatment and gynecological intracavitary brachytherapy were computed with a refined numerical algorithm. Results of the analytic models and the numerical calculations demonstrated that the difference between the DWH and DSH was small (about 5%) for a fully filled bladder or rectum but large (about 10%) for an empty rectum or a contracted bladder. The error of DSH was about 3%, which is much smaller than that of DWH. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:1107 / 1116
页数:10
相关论文
共 14 条
  • [1] A NATURAL VOLUME-DOSE HISTOGRAM FOR BRACHYTHERAPY
    ANDERSON, LL
    [J]. MEDICAL PHYSICS, 1986, 13 (06) : 898 - 903
  • [2] [Anonymous], 1993, 50 ICRU
  • [3] DOSE VOLUME HISTOGRAM ANALYSIS OF LIVER RADIATION TOLERANCE
    AUSTINSEYMOUR, MM
    CHEN, GTY
    CASTRO, JR
    SAUNDERS, WM
    PITLUCK, S
    WOODRUFF, KH
    KESSLER, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (01): : 31 - 35
  • [4] BOYER A, 1996, INT J RADIAT ONCOL, V34, P390
  • [5] DRZYMALA RE, 1991, INT J RADIAT ONCOL, V22, P137
  • [6] International Commission on Radiological Protection, 1975, REPORT TASK GROUP RE
  • [7] LI S, 1995, THESIS U CHICAGO
  • [8] DOSE-SURFACE HISTOGRAMS AS TREATMENT PLANNING TOOL FOR PROSTATE CONFORMAL THERAPY
    LU, Y
    LI, S
    SPELBRING, D
    SONG, P
    VIJAYAKUMAR, S
    PELIZZARI, C
    CHEN, GTY
    [J]. MEDICAL PHYSICS, 1995, 22 (03) : 279 - 284
  • [9] A method of analyzing rectal surface area irradiated and rectal complications in prostate conformal radiotherapy
    Lu, Y
    Song, PY
    Li, SD
    Spelbring, DR
    Vijayakumar, S
    Haraf, DJ
    Chen, GTY
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1121 - 1125
  • [10] COMPLICATION PROBABILITY AS ASSESSED FROM DOSE VOLUME HISTOGRAMS
    LYMAN, JT
    [J]. RADIATION RESEARCH, 1985, 104 (02) : S13 - S19