Mechanistic and spatial study of ultrasonically induced luminol chemiluminescence

被引:116
作者
McMurray, HN [1 ]
Wilson, BP [1 ]
机构
[1] Univ Wales Swansea, Dept Mat Engn, Swansea SA2 8PP, W Glam, Wales
关键词
D O I
10.1021/jp984503r
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Aqueous solutions containing 10(-3) M luminol and varying concentrations of hydrogen peroxide are irradiated with 20 kHz ultrasound at 50 degrees C. The intensity of sonogenerated chemiluminescence (SCL) is shown to increase linearly with ultrasound power and to be strongly pH dependent, reaching a maximum at pH 12. For pH < 10 SCL intensity (I-SCL) is independent of H2O2 concentration. For pH > 10 I-SCL increases monotonically with H2O2 concentration up to 10(-4) M but decreases as the concentration is increased further. A mechanism is proposed in which HO2- and the luminol monoanion competitively reduce sonochemically generated HO., producing O-2(.-) and luminol radical anion, respectively. Luminescence follows the decomposition of a hydroperoxide adduct formed by reaction between O-2(.-) and luminol radical anion. EDTA is shown to suppress the background (silent) chemiluminescence of solutions containing luminol and H2O2 without significantly affecting I-SCL Digital images of SCL emission occurring near the transducer-solution interface are analyzed to determine the spatial distribution of sonochemical activity. It is shown that, in the absence of standing waves, I-SCL decays exponentially with perpendicular distance from the surface of a plane-ended ultrasound transducer hem. Spatially resolved I-SCL data is used to determine the acoustic attenuation coefficient (alpha) in acoustically cavitating water noninvasively. It is shown that or values at the cavitation-producing frequency increase with transducer output power and may be many orders of magnitude greater than is the case for homogeneous water.
引用
收藏
页码:3955 / 3962
页数:8
相关论文
共 51 条
[1]  
Apfel RE., 1981, METHODS EXPT PHYSICS, P355, DOI [DOI 10.1016/S0076-695X(08)60338-5, 10.1016/S0076-695X(08)60338-5]
[2]   LIGHT-SCATTERING MEASUREMENTS OF THE REPETITIVE SUPERSONIC IMPLOSION OF A SONOLUMINESCING BUBBLE [J].
BARBER, BP ;
PUTTERMAN, SJ .
PHYSICAL REVIEW LETTERS, 1992, 69 (26) :3839-3842
[3]   PULSE-RADIOLYSIS STUDY OF CHEMILUMINESCENCE FROM LUMINOL - (5-AMINO-2,3-DIHYDRRPHTHALAZINE-1,4-DIONE) [J].
BAXENDAL.JH .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1973, (09) :1665-1677
[4]  
BAXENDALE JH, 1964, RADIATION RES S, V4, P114
[5]   THE EFFECT OF BUFFERS AND CHELATORS ON THE REACTION OF LUMINOL WITH FENTON REAGENT NEAR NEUTRAL PH [J].
BOTTU, G .
JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1991, 6 (03) :147-151
[6]  
BUXTON GV, 1987, RADIAT PHYS CHEM, V29, P137
[7]  
BUXTON GV, 1986, RADIAT PHYS CHEM, V27, P241
[8]   CRITICAL-REVIEW OF RATE CONSTANTS FOR REACTIONS OF HYDRATED ELECTRONS, HYDROGEN-ATOMS AND HYDROXYL RADICALS (.OH/.O-) IN AQUEOUS-SOLUTION [J].
BUXTON, GV ;
GREENSTOCK, CL ;
HELMAN, WP ;
ROSS, AB .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1988, 17 (02) :513-886
[9]   Effect of frequency on sonochemical reactions .2. Temperature and intensity effects [J].
Entezari, MH ;
Kruus, P .
ULTRASONICS SONOCHEMISTRY, 1996, 3 (01) :19-24
[10]   LUMINOL AS FLUORESCENT ACID-BASE INDICATOR [J].
ERDEY, L ;
BUZAS, I ;
VIGH, K .
TALANTA, 1966, 13 (03) :463-&