A broadly applicable approach to prepare monoclonal anti-cephalosporin antibodies for immunochemical residue determination in milk

被引:30
作者
Bremus, Anna [1 ]
Dietrich, Richard [1 ]
Dettmar, Lars [1 ]
Usleber, Ewald [2 ]
Maertlbauer, Erwin [1 ]
机构
[1] Univ Munich, Chair Hyg & Technol Milk, Dept Vet Sci, D-85764 Oberschleissheim, Germany
[2] Univ Giessen, Fac Vet, Chair Dairy Sci, D-35390 Giessen, Germany
关键词
Cephalosporins; Enzyme immunoassay; Milk; Monoclonal antibodies; Residues; BETA-LACTAM ANTIBIOTICS; LINKED-IMMUNOSORBENT-ASSAY; IMMUNOANALYSIS SYSTEM; CEFTIOFUR SODIUM; DRUG RESIDUES; CHROMATOGRAPHY; CEPHALEXIN; VALIDATION; ELISA; FOOD;
D O I
10.1007/s00216-012-5750-z
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
A simple, efficient and rapid method for the synthesis of cephalosporin-protein conjugates was established. These conjugates were used as immunogens to produce monoclonal antibodies (mAbs) and as solid phase antigens in competitive indirect enzyme immunoassays (EIAs). With this generic approach, a novel set of monoclonal antibodies for cephalosporins was prepared, including ceftiofur and cephalexin as well as, reported here for the first time, cefoperazone, cefquinome and cephapirin. All 5 EIAs were highly sensitive, with standard curve IC50 values of 0.7 (ceftiofur), 1.1 (cefquinome), 5.2 (cephalexin), 13.8 (cefoperazone) and 40.3 ng mL(-1) (cephapirin). Detection limits (IC30) ranged from 0.3 (ceftiofur mAb 1D7) to 17.2 ng mL(-1) (cephapirin mAb 2F10). Specificity studies revealed that cephalosporin-antibody binding was strongly determined by the side chain residues of the cephem nucleus. Therefore all mAbs, to some extent, recognized other beta-lactam antibiotics with similar side chain residues. Within the group of cephalosporins approved for use in veterinary medicine, however, the final EIAs were highly selective for their respective antigen, except for the ceftiofur EIA which showed cross-reactions with cefquinome. The applicability of the five assays for drug residue testing in milk was demonstrated. In each EIA the target drug could be determined in milk with high accuracy and precision at concentrations far below the European Union maximum residue limits.
引用
收藏
页码:503 / 515
页数:13
相关论文
共 42 条
[1]
Abouzied M, 2009, J AOAC INT, V92, P959
[2]
Residue analysis of 15 penicillins and cephalosporins in bovine muscle, kidney and milk by liquid chromatography-tandem mass spectrometry [J].
Becker, M ;
Zittlau, E ;
Petz, M .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :19-32
[3]
BASIS FOR THE EVALUATION OF THE MICROBIOLOGICAL RISKS DUE TO VETERINARY DRUG RESIDUES IN FOOD [J].
BOISSEAU, J .
VETERINARY MICROBIOLOGY, 1993, 35 (3-4) :187-192
[4]
Solid-phase extraction followed by liquid chromatography-mass spectrometry for trace determination of β-lactam antibiotics in bovine milk [J].
Bruno, F ;
Curini, R ;
Di Corcia, A ;
Nazzari, M ;
Samperi, R .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (07) :3463-3470
[5]
Development of an optical biosensor assay for detection of β-lactam antibiotics in milk using the penicillin-binding protein 2x [J].
Cacciatore, G ;
Petz, M ;
Rachid, S ;
Hakenbeck, R ;
Bergwerff, AA .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :105-115
[6]
Cephalexin Residue Detection in Milk and Beef by ELISA and Colloidal Gold Based One-Step Strip Assay [J].
Chen, Liben ;
Wang, Zhengfang ;
Ferreri, Miro ;
Su, Jingliang ;
Han, Bo .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (11) :4674-4679
[7]
Extended-spectrum β-lactamases, food, and cephalosporin use in food animals [J].
Collignon, Peter ;
Aarestrup, Frank M. .
CLINICAL INFECTIOUS DISEASES, 2007, 44 (10) :1391-1392
[8]
Daeseleire E, 2000, RAPID COMMUN MASS SP, V14, P1404, DOI 10.1002/1097-0231(20000815)14:15<1404::AID-RCM38>3.3.CO
[9]
2-W
[10]
RISK ASSESSMENT OF ANTIBIOTIC RESIDUES OF BETA-LACTAMS AND MACROLIDES IN FOOD-PRODUCTS WITH REGARD TO THEIR IMMUNOALLERGIC POTENTIAL [J].
DEWDNEY, JM ;
MAES, L ;
RAYNAUD, JP ;
BLANC, F ;
SCHEID, JP ;
JACKSON, T ;
LENS, S ;
VERSCHUEREN, C .
FOOD AND CHEMICAL TOXICOLOGY, 1991, 29 (07) :477-483