A NURBS-based technique for subject-specific construction of knee bone geometry

被引:14
作者
Au, Anthony G. [1 ]
Palathinkal, Darren [1 ]
Liggins, Adrian B.
Raso, V. James
Carey, Jason [1 ]
Lambert, Robert G. [2 ]
Amirfazli, A. [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Edmonton, AB T6G 2G8, Canada
[2] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB T6G 2G8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
finite element modeling; computed tomography; subject-specific; knee; bone geometry construction; laser scan;
D O I
10.1016/j.cmpb.2008.05.009
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
Subject-specific finite element (FE) models of bones that form the knee joint require rapid and accurate geometry construction. The present study introduces a semi-automatic nonuniform rational B-spline (NURBS) technique to construct knee bone geometries from computed tomography (CT) images using a combination of edge extraction and CAD surface generation. In particular, this technique accurately constructs endosteal surfaces and can accommodate thin cortical bone by estimating the cortical thickness from well-defined surrounding bone. A procedure is also introduced to overcome the bifurcation at the femoral condyles during surface generation by combining transverse and sagittal plane CT data. Available voxel- and NURBS-based subject-specific construction techniques accurately capture periosteal surfaces but are limited in their ability to capture endosteal geometry. In this study, the proposed NURBS-based technique and a typical voxel mesh technique captured periosteal surfaces within an order of magnitude of image resolution. The endosteum of diaphyseal bone was also captured with similar accuracy by both techniques. However, the voxel mesh model failed to accurately capture the metaphyseal and epiphyseal endosteum due to the poor CT contrast of thin cortical bone, resulting in gross overestimation of cortical thickness. The proposed technique considered both the local and global nature of CT images to arrive at a description of cortical bone thickness accurate to within 2 pixel lengths. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:20 / 34
页数:15
相关论文
共 38 条
[1]
Subject-specific finite element model of the pelvis: Development, validation and sensitivity studies [J].
Anderson, AE ;
Peters, CL ;
Tuttle, BD ;
Weiss, JA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03) :364-373
[2]
[Anonymous], 1997, ALGORITHMS IMAGE PRO
[3]
ANALYSIS OF MODEL VARIABLES AND FIXATION POST LENGTH EFFECTS ON STRESSES AROUND A PROSTHESIS IN THE PROXIMAL TIBIA [J].
ASKEW, MJ ;
LEWIS, JL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (04) :239-245
[4]
A parametric analysis of fixation post shape in tibial knee prostheses [J].
Au, AG ;
Liggins, AB ;
Raso, VJ ;
Amirfazli, A .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (02) :123-134
[5]
EPIPHYSEAL-BASED DESIGNS FOR TIBIAL PLATEAU COMPONENTS .2. STRESS-ANALYSIS IN THE SAGITTAL PLANE [J].
BEAUPRE, GS ;
VASU, R ;
CARTER, DR ;
SCHURMAN, DJ .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :663-673
[6]
An improved method for finite element mesh generation of geometrically complex structures with application to the skullbase [J].
Camacho, DLA ;
Hopper, RH ;
Lin, GM ;
Myers, BS .
JOURNAL OF BIOMECHANICS, 1997, 30 (10) :1067-1070
[7]
COLEMAN JC, 2000, TUBONE200003
[8]
Curry III T.S., 1990, Christensen's Physics of Diagnostic Radiology, Vfourth
[9]
CONSEQUENCES OF AN INTERFERENCE FIT ON THE FIXATION OF POROUS-COATED TIBIAL COMPONENTS IN TOTAL KNEE REPLACEMENT [J].
DAWSON, JM ;
BARTEL, DL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (02) :233-238
[10]
Ultrasound imaging in lower limb prosthetics [J].
Douglas, TS ;
Solomonidis, S ;
Sandham, W ;
Spence, W .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2002, 10 (01) :11-21