Solid-phase microextraction using poly(pyrrole) film and liquid chromatography with UV detection for analysis of antidepressants in plasma samples

被引:81
作者
Chaves, Andrea Rodrigues [1 ]
Chiericato Junior, Glaico [1 ]
Costa Queiroz, Maria Eugema [1 ]
机构
[1] Univ Sao Paulo, Dept Quim, Fac Filosofia Ciencias & Letras Ribeirao Pret, BR-14040903 Ribeirao Preto, SP, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2009年 / 877卷 / 07期
基金
巴西圣保罗研究基金会;
关键词
Antidepressants; Poly(pyrrole); SPME; Liquid chromatography; TRICYCLIC ANTIDEPRESSANTS; NONTRICYCLIC ANTIDEPRESSANTS; GAS-CHROMATOGRAPHY; MASS-SPECTROMETRY; POLYPYRROLE FILMS; ACTIVE METABOLITES; HPLC METHOD; EXTRACTION; SPME; SERUM;
D O I
10.1016/j.jchromb.2008.12.070
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Poly(pyrrole) (PPY) coating was prepared on a stainless-steel (SS) wire for solid-phase microextraction (SPME) by electrochemical deposition (cyclic voltammetric). The PPY was evaluated by analyzing new-generation antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline) in plasma sample by SPME and liquid chromatography with UV detection (LC-UV). The effect of electrolyte Solution (lithium perchlorate or tetrabutylammonium perchlorate) and the number of cycles (50, 100 or 200) applied during the polymerization process on the SPME performance was evaluated. Important factors in the optimization of SPME efficiency such as extraction time, temperature, pH, influence of plasma proteins on sorption mechanisms, and desorption conditions are discussed. The SPME-PPY/LC method showed to be linear in concentrations ranging from the limit of quantification (LOQ) to 1200 ng mL(-1). The LOQ values range from 16 to 25 ng mL-1. The inter-day precision of the SPME-PPY/LC method presented coefficient of variation (CV) lower than 15%. Based on analytical validation results, the SPME-PPY/LC methodology showed to be adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the SPME-PPY/LC method was applied to the analysis of plasma samples from elderly depressed patients. (c) 2009 Elsevier B.V. All rights reserved,
引用
收藏
页码:587 / 593
页数:7
相关论文
共 40 条
[1]
Rapid screening of methamphetamines in human serum by headspace solid-phase microextraction using a dodecylsulfate-doped polypyrrole film coupled to ion mobility spectrometry [J].
Alizadeh, Naader ;
Mohammadi, Abdorreza ;
Tabrizchi, Mahmoud .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1183 (1-2) :21-28
[2]
Optimization of the SPME parameters and its online coupling with HPLC for the analysis of tricyclic antidepressants in plasma samples [J].
Alves, Claudete ;
Fernandes, Christian ;
Santos-Neto, Alvaro Jose ;
Rodrigues, Jose Carlos ;
Costa Queiroz, Maria Eugenia ;
Lancas, Fernando Mauro .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2006, 44 (06) :340-346
[3]
SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[4]
Solid-phase extraction with liquid chromatography and ultraviolet detection for the assay of antidepressant drugs in human plasma [J].
Bakkali, A ;
Corta, E ;
Ciria, JI ;
Berrueta, LA ;
Gallo, B ;
Vicente, F .
TALANTA, 1999, 49 (04) :773-783
[5]
Optimization of solid-phase microextraction procedures for the determination of tricyclic antidepressants and anticonvulsants in plasma samples by liquid chromatography [J].
Cantu, Marcelo Delmar ;
Toso, Daniel Rodrigo ;
Lacerda, Cristina Alves ;
Lancas, Fernando Mauro ;
Carrilho, Emanuel ;
Queiroz, Maria Eugenia Costa .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (02) :256-263
[6]
Validation of non-aqueous capillary electrophoresis for simultaneous determination of four tricyclic antidepressants in pharmaceutical formulations and plasma samples [J].
Cantú, MD ;
Hillebrand, S ;
Queiroz, MEC ;
Lanças, FM ;
Carrilho, E .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (01) :127-132
[7]
Stir bar sorptive extraction and liquid chromatography with UV detection for determination of antidepressants in plasma samples [J].
Chaves, Andrea Rodrigues ;
Silva, Silvana Maciel ;
Costa Queiroz, Regina Helena ;
Lancas, Fernando Mauro ;
Costa Queiroz, Maria Eugnia .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2) :295-302
[8]
LC-MS/MS method for the determination of nine antidepressants and some of their main metabolites in oral fluid and plasma -: Study of correlation between venlafaxine concentrations in both matrices [J].
de Castro, A. ;
Concheiro, M. ;
Quintela, O. ;
Cruz, A. ;
Lopez-Rivadulla, M. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (01) :183-193
[9]
High-throughput on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry method for the simultaneous analysis of 14 antidepressants and their metabolites in plasma [J].
de Castro, Ana ;
Femandez, Maria Del Mar Ramirez ;
Laloup, Marleen ;
Samyn, Nele ;
De Boeck, Gert ;
Wood, Michelle ;
Maes, Viviane ;
Lopez-Rivadulla, Manuel .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1160 (1-2) :3-12
[10]
Analysis of eighteen antidepressants, four atypical antipsychotics and active metabolites in serum by liquid chromatography:: a simple tool for therapeutic drug monitoring [J].
Frahnert, C ;
Rao, ML ;
Grasmäder, K .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (01) :35-47