Simultaneous determination of some water-soluble vitamins and preservatives in multivitamin syrup by validated stability-indicating high-performance liquid chromatography method

被引:82
作者
Vidovic, Stojanka [1 ]
Stojanovic, Bijana
Veljkovic, Jelena
Prazic-Arsic, Ljiljana
Roglic, Goran [2 ]
Manojlovic, Dragan [2 ]
机构
[1] Batajnicki Drum Bb, Galenika Ad, Ctr Analyt & Stabil, Belgrade 11070, Serbia
[2] Univ Belgrade, Fac Chem, Belgrade 11000, Serbia
关键词
water-soluble vitamins; preservatives; HPLC stability-indicating; stress testing; multivitamin syrup;
D O I
10.1016/j.chroma.2008.06.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
HPLC stability-indicating method has been developed for the simultaneous determination of some water-soluble vitamins (ascorbic acid, thiamine hydrochloride, riboflavin-5'-phosphate sodium, pyridoxine hydrochloride, nicotinamide, D(+)-panthenol) and two preservatives (methylparaben and sodium benzoate) in multivitamin syrup preparation. Water-soluble vitamins, preservatives and their degradants were separated on Zorbax SB-Aq (C-18) (250 mm x 4.6 mm, 5 mu m) column at an ambient temperature. Combined isocratic and gradient elution was performed with a mobile phase consisting of 0.0125M hexane-1-sulfonic acid sodium salt in 0.1% (m/v) o-phosphoric acid, pH 2.4-2.5 (solvent A) and acetonitrile (solvent B) at the flow-rate 1 ml min(-1). Starting with solvent A an isocratic elution was performed for 15 min, then the composition was changed to 85% of A and 15% of B during the next 20 min and it was constant for 5 min, then the composition was changed to 70% of A and 30% of B during next 15 min and it was constant for 5 min and finally was changed to 100% of A as at the beginning of the elution. Detection was performed with diode array detector at 210, 230 and 254 nm. Multivitamin syrup preparation was subjected to stress testing (forced degradation) in order to demonstrate that degradants from the vitamins, preservatives and/or product excipients do not interfere with the quantification of vitamins and preservatives. Typical validation characteristics: selectivity, accuracy, precision, linearity, range, limit of quantification and limit of detection were evaluated for vitamins and preservatives. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 32 条
[1]   Determination of water-soluble vitamins in infant milk by high-performance liquid chromatography [J].
AlbalaHurtado, S ;
VecianaNogues, MT ;
IzquierdoPulido, M ;
MarineFont, A .
JOURNAL OF CHROMATOGRAPHY A, 1997, 778 (1-2) :247-253
[2]   Stability indicating simultaneous determination of domperidone (DP), methylparaben (MP) and propylparaben by high performance liquid chromatography (HPLC) [J].
Ali, MS ;
Ghori, M ;
Khatri, AR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) :358-365
[3]  
[Anonymous], 2003, Q1A (R2), current step, V4, P1, DOI DOI 10.1136/BMJ.333.7574.873-A
[4]   Simple high-performance liquid chromatographic method for the determination of all seven vitamin B6 related compounds [J].
Argoudelis, CJ .
JOURNAL OF CHROMATOGRAPHY A, 1997, 790 (1-2) :83-91
[5]   Determination of vitamin B6 vitamers and pyridoxic acid in plasma: Development and evaluation of a high-performance liquid chromatographic assay [J].
Bisp, MR ;
Bor, MV ;
Heinsvig, EM ;
Kall, MA ;
Nexo, E .
ANALYTICAL BIOCHEMISTRY, 2002, 305 (01) :82-89
[6]  
Center for Drug Evaluation and Research (CDER), 1994, REV GUID VAL CHROM M, P23
[7]  
*CH, 1994, Q2A ICH, P4
[8]   Development of a validated HPLC method for the determination of B-complex vitamins in pharmaceuticals and biological fluids after solid phase extraction [J].
Chatzimichalakis, PF ;
Samanidou, VF ;
Verpoorte, R ;
Papadoyannis, IN .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (14) :1181-1188
[9]   Simultaneous determination of water-soluble vitamins excreted in human urine after eating an overdose of vitamin pills by a HPLC method coupled with a solid phase extraction [J].
Cho, CM ;
Ko, JH ;
Cheong, WJ .
TALANTA, 2000, 51 (04) :799-806
[10]  
*CPMP QWP, 2003, CPMPQWP12202, P3