摘要
Our primary goal in this study is to demonstrate that near-infrared Raman spectroscopy is feasible as a rapid and reagentless analytic method for clinical diagnostics. Raman spectra were collected on human sera by use of a 785-nm excitation laser and st single-stage holographic spectrometer. A partial-least-squares method was used to predict the analyte concentrations of interest. The prediction errors of total protein, albumin, triglyceride, and glucose in human sera ranged from 1.0% to 10%, which are highly acceptable for clinical diagnosis, of their mean physiological levels. For investigating the potential application of near-infrared Raman spectroscopy in screening of therapeutical drugs and substances of abuse the concentrations of acetaminophen, ethanol, and codeine in water solution were measured in the same fashion. The errors of the Raman tests for acetaminophen and ethanol are lower than their toxic levels in human serum, and the sensitivity for detection of codeine fails to reach its toxic level. (C) 1999 Optical Society of America.
引用
收藏
页码:5491 / 5498
页数:8
相关论文
共 26 条
[1]  
[Anonymous], STRUCTURES PROPERTIE
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]   Multicomponent blood analysis by near-infrared Raman spectroscopy [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Horowitz, G ;
Feld, MS .
APPLIED OPTICS, 1999, 38 (13) :2916-2926
[4]   An enhanced algorithm for linear multivariate calibration [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Feld, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :623-627
[5]   Rapid, noninvasive concentration measurements of aqueous biological analytes by near-infrared Raman spectroscopy [J].
Berger, AJ ;
Wang, Y ;
Feld, MS .
APPLIED OPTICS, 1996, 35 (01) :209-212
[6]   Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy [J].
Berger, AJ ;
Itzkan, I ;
Feld, MS .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1997, 53 (02) :287-292
[7]   SIMULATION OF THE INTERMOLECULAR VIBRATIONAL-SPECTRA OF LIQUID WATER AND WATER CLUSTERS [J].
BOSMA, WB ;
FRIED, LE ;
MUKAMEL, S .
JOURNAL OF CHEMICAL PHYSICS, 1993, 98 (06) :4413-4421
[8]   RAMAN FREQUENCY AND INTENSITY STUDIES OF LIQUID H2O, (H2O)-O-18 AND D2O [J].
BROOKER, MH ;
HANCOCK, G ;
RICE, BC ;
SHAPTER, J .
JOURNAL OF RAMAN SPECTROSCOPY, 1989, 20 (10) :683-694
[9]  
DEUTSCH DG, 1989, ANAL ASPECTS DRUG TE
[10]   Quantitative analysis of metabolites in urine using a highly precise, compact near-infrared Raman spectrometer [J].
Dou, X ;
Yamaguchi, Y ;
Yamamoto, H ;
Doi, S ;
Ozaki, Y .
VIBRATIONAL SPECTROSCOPY, 1996, 13 (01) :83-89