Effect of Bioimpedance Body Composition Analysis on Function of Implanted Cardiac Devices

被引:23
作者
Buch, Eric [1 ]
Bradfield, Jason [1 ]
Larson, Tianne [2 ]
Horwich, Tamara [2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, UCLA Cardiac Arrhythmia Ctr, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Ahmanson UCLA Cardiomyopathy Ctr, Ronald Reagan UCLA Med Ctr, Los Angeles, CA 90095 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2012年 / 35卷 / 06期
关键词
implantable cardioverter defibrillator; heart failure; device interaction; bioimpedance analysis; body composition analysis; BIOELECTRICAL-IMPEDANCE ANALYSIS; CHRONIC HEART-FAILURE; CARDIOVERTER-DEFIBRILLATORS; INTERFERENCE; PACEMAKERS; MORTALITY; RISK;
D O I
10.1111/j.1540-8159.2012.03377.x
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background: It is routinely recommended that patients with pacemakers, implantable cardioverter defibrillators (ICD), and cardiac resynchronization therapy-defibrillators (CRT-D) avoid bioelectrical impedance analysis (BIA)a commonly used method to estimate body compositionbecause of the concern for the potential for BIA interference with pacemaker or ICD function. However, the prevalence of such interference is not known. Objective: Assess for incidence of interference between BIA and ICD or CRT-D devices. Methods and Results: Twenty patients with heart failure and cardiac implanted electronic devices (50% ICD, 50% CRT-D) underwent BIA during real-time device interrogation to detect interference. Study patients were 90% male, with mean age 54 +/-14 years, and mean LVEF 23 +/- 11%. Devices from all four leading cardiac device manufacturers were included. Device therapies were temporarily disabled to prevent inappropriate shocks. During body composition testing using BIA, no evidence of interference with ICD function was seen in any patient, including no telemetry disruption, no oversensing on any lead, and no patient symptoms. Conclusions: Despite the manufacturers recommendation to avoid BIA in patients with ICDs, this study showed no evidence of any interference in 20 patients. Bioimpedance analysis might be safe in such patients, but further confirmatory studies are required. (PACE 2012; 35:681684)
引用
收藏
页码:681 / 684
页数:4
相关论文
共 16 条
[1]
Wasting as independent risk factor for mortality in chronic heart failure [J].
Anker, SD ;
Ponikowski, P ;
Varney, S ;
Chua, TP ;
Clark, AL ;
WebbPeploe, KM ;
Harrington, D ;
Kox, WJ ;
PooleWilson, PA ;
Coats, AJS .
LANCET, 1997, 349 (9058) :1050-1053
[2]
Bioelectrical impedance and strength measurements in patients with heart failure:: comparison with functional class [J].
Castillo Martinez, Lilia ;
Colin Ramirez, Eloisa ;
Orea Tejeda, Arturo ;
Asensio Lafuente, Enrique ;
Bernal Rosales, Laura Paola ;
Rebollar Gonzalez, Veronica ;
Narvaez David, Rene ;
Dorantes Garcia, Joel .
NUTRITION, 2007, 23 (05) :412-418
[3]
Assessing Adiposity A Scientific Statement From the American Heart Association [J].
Cornier, Marc-Andre ;
Despres, Jean-Pierre ;
Davis, Nichola ;
Grossniklaus, Daurice A. ;
Klein, Samuel ;
Lamarche, Benoit ;
Lopez-Jimenez, Francisco ;
Rao, Goutham ;
St-Onge, Marie-Pierre ;
Towfighi, Amytis ;
Poirier, Paul .
CIRCULATION, 2011, 124 (18) :1996-2019
[4]
Electromagnetic interference from wireless video-capsule endoscopy on implantable cardioverter-defibrillators [J].
Dubner, Sergio ;
Dubner, Yael ;
Rubio, Horacio ;
Goldin, Eran .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (04) :472-475
[5]
Left Ventricular Mechanical Assist Devices and Cardiac Device Interactions: An Observational Case Series [J].
Foo, David ;
Walker, Bruce D. ;
Kuchar, Dennis L. ;
Thorburn, Charles W. ;
Tay, Andre ;
Hayward, Christopher S. ;
Macdonald, Peter ;
Keogh, Anne ;
Kotlyar, Eugene ;
Spratt, Philip ;
Jansz, Paul .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (07) :879-887
[6]
Interference with cardiac pacemakers by cellular telephones [J].
Hayes, DL ;
Wang, PJ ;
Reynolds, DW ;
Estes, NAM ;
Griffith, JL ;
Steffens, RA ;
Carlo, GL ;
Findlay, GK ;
Johnson, CM .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (21) :1473-1479
[7]
Risk of interference from transcutaneous electrical nerve stimulation on the sensing function of implantable defibrillators [J].
Holmgren, Christina ;
Carlsson, Tobias ;
Mannheimer, Clas ;
Edvardsson, Nils .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (02) :151-158
[8]
The relationship between obesity and mortality in patients with heart failure [J].
Horwich, TB ;
Fonarow, GC ;
Hamilton, MA ;
MacLellan, WR ;
Woo, MA ;
Tillisch, JH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) :789-795
[9]
Body composition determination by bioimpedance: an update [J].
Jaffrin, Michel Y. .
CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2009, 12 (05) :482-486
[10]
Bioelectrical impedance analysis -: part II:: utilization in clinical practice [J].
Kyle, UG ;
Bosaeus, I ;
De Lorenzo, AD ;
Deurenberg, P ;
Elia, M ;
Gómez, JM ;
Heitmann, BL ;
Kent-Smith, L ;
Melchior, JC ;
Pirlich, M ;
Scharfetter, H ;
Schols, AMWJ ;
Pichard, C .
CLINICAL NUTRITION, 2004, 23 (06) :1430-1453