Four-dimensional proton treatment planning for lung tumors

被引:103
作者
Engelsman, M
Rietzel, E
Kooy, HM
机构
[1] Maastro Clin, NL-6419 PC Heerlen, Netherlands
[2] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02115 USA
[3] Biophys Abt, Gesell Schwerionenforsch, Darmstadt, Germany
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 05期
关键词
four-dimensional computed tomography; proton; treatment planning; lung;
D O I
10.1016/j.ijrobp.2005.12.026
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In proton radiotherapy, respiration-induced variations in density lead to changes in radiologic path lengths and will possibly result in geometric misses. We compared different treatment planning strategies for lung tumors that compensate for respiratory motion. Methods and Materials: Particle-specific treatment planning margins were applied to standard helical computed tomography (CT) scans as well as to "representative" CT scans. Margins were incorporated beam specific laterally by aperture widening and longitudinally by compensator smearing. Furthermore, treatment plans using full time-resolved 4D-computed tomography data were generated. Results: Four-dimensional treatment planning guaranteed target coverage throughout a respiratory cycle. Use of a standard helical CT data set resulted in underclosing the target volume to 36% or the prescribed dose. For CT data representing average target positions, coverage call be expected but not guaranteed. In comparison to this strategy, 4D planning decreased the mean lung dose by tip to 16% and the lung volume receiving 20 Gy (prescribed target dose 72 Gy) by up to 15%. Conclusion: When the three planning strategies are compared., only 4D proton treatment planning guarantees delivery of the prescribed dose throughout a respiratory cycle. Furthermore, the 4D planning approach results in equal or reduced dose to critical structures; even the ipsilateral lung is spared. (c) 2006 Elsevier Inc.
引用
收藏
页码:1589 / 1595
页数:7
相关论文
共 24 条
[1]   Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates [J].
Berbeco, RI ;
Nishioka, S ;
Shirato, H ;
Chen, GTY ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) :3655-3667
[2]   Effects of proton and combined proton photon beam radiation on pulmonary function in patients with resectable but medically inoperable non-small cell lung cancer [J].
Bonnet, RB ;
Bush, D ;
Cheek, GA ;
Slater, JD ;
Panossian, D ;
Franke, C ;
Slater, JM .
CHEST, 2001, 120 (06) :1803-1810
[3]   Hypofractionated proton beam radiotherapy for stage I lung cancer [J].
Bush, DA ;
Slater, JD ;
Shin, BB ;
Cheek, G ;
Miller, DW ;
Slater, JM .
CHEST, 2004, 126 (04) :1198-1203
[4]   Proton-beam radiotherapy for early-stage lung cancer [J].
Bush, DA ;
Slater, JD ;
Bonnet, R ;
Cheek, GA ;
Dunbar, RD ;
Moyers, M ;
Slater, JM .
CHEST, 1999, 116 (05) :1313-1319
[5]   Pulmonary injury from proton and conventional radiotherapy as revealed by CT [J].
Bush, DA ;
Dunbar, RD ;
Bonnet, R ;
Slater, JD ;
Cheek, GA ;
Slater, JM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (03) :735-739
[6]   What can we expect from dose escalation using proton beams? [J].
Fowler, JF .
CLINICAL ONCOLOGY, 2003, 15 (01) :S10-S15
[7]   3D online compensation of target motion with scanned particle beam [J].
Grözinger, SO ;
Li, Q ;
Rietzel, E ;
Haberer, T ;
Kraft, G .
RADIOTHERAPY AND ONCOLOGY, 2004, 73 :S77-S79
[8]   A pencil beam algorithm for proton dose calculations [J].
Hong, L ;
Goitein, M ;
Bucciolini, M ;
Comiskey, R ;
Gottschalk, B ;
Rosenthal, S ;
Serago, C ;
Urie, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08) :1305-1330
[9]  
*INT COMM RAD UN M, 1999, 62 ICRU INT COMM RAD
[10]  
Kagei Kenji, 2004, Nippon Acta Radiologica, V64, P225