Calibration cell for E-field sensors in water environment

被引:10
作者
Berger, J
Pouhè, D
Mönich, G
Fähling, H
Wust, P
Petermann, K
机构
[1] Tech Univ Berlin, Dept Radio Frequency Engn, D-10587 Berlin, Germany
[2] Charite Berlin, Dept Radiat Oncol, D-13353 Berlin, Germany
关键词
D O I
10.1049/el:19990924
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Compact and nonperturbing E-field sensors are used for antenna near field measurements. For application in the research area of hyperthermia these sensors are used in a water environment. Owing to the high dielectric constant of water in the frequency range from DC to similar to 1GHz the sensitivity is changed. To perform a calibration of E-fieid sensors, a water-filled TEM-cell has been developed. The technique employs a transverse electromagnetic (TEM) transmission cell that operates as a 50W impedance matched system. A uniform TEM-field is established inside the cell.
引用
收藏
页码:1317 / 1318
页数:2
相关论文
共 6 条
[1]   ELECTRIC-FIELD PROBES - A REVIEW [J].
BASSEN, HI ;
SMITH, GS .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1983, 31 (05) :710-718
[2]  
Brun W, 1997, P PART ACC C PAC 97, P2651, DOI 10.1109/PAC.1997.751304
[3]   LINEAR INTERFEROMETRIC WAVE-GUIDE MODULATOR FOR ELECTROMAGNETIC-FIELD DETECTION [J].
BULMER, CH ;
BURNS, WK ;
MOELLER, RP .
OPTICS LETTERS, 1980, 5 (05) :176-178
[4]  
CRAWFORD ML, 1974, IEEE T EMC, V16, P185
[5]  
KONIGSTEIN D, 1987, 7 INT ZUR S EL COMP, P127
[6]   DEVELOPMENT AND ANALYSIS OF ELECTRIC-FIELD SENSOR USING LINBO3 OPTICAL MODULATOR [J].
KUWABARA, N ;
TAJIMA, K ;
KOBAYASHI, R ;
AMEMIYA, F .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1992, 34 (04) :391-396