Long length calorimetric measurement of AC losses of Bi-2223 with external field oriented perpendicular to the tape width.

被引:4
作者
Snitchler, G
Campbell, J
Aized, D
SidiYekhlef, A
Fleshler, S
Kalsi, S
Schwall, R
机构
[1] American Superconductor Corporation, Westborough
关键词
D O I
10.1109/77.614487
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
AC applications are projected to be a significant market for HTS conductor. The ac magnetic fields perpendicular to the wide face of Bi-2223 conductor (or parallel to the crystallographic c-axis of the oxide superconductor) are responsible for a significant portion of the total loss in ac coils. ASC has developed a calorimetric apparatus which can measure long lengths of conductor in a uniform continuous perpendicular field. This apparatus provides accurate measurement of interfilament or interstrand coupling losses. Calorimetric measurements from long lengths of twisted multifilamentary conductor are presented.
引用
收藏
页码:290 / 293
页数:4
相关论文
共 4 条
[1]  
AIZED D, 1995, P ICMC CEC C
[2]   ALTERNATING-CURRENT LOSSES IN SILVER-SHEATHED (BI,PB)(2)SR2CA2CU3O10 TAPES .2. ROLE OF INTERFILAMENTARY COUPLING [J].
FUKUMOTO, Y ;
WIESMANN, HJ ;
GARBER, M ;
SUENAGA, M ;
HALDAR, P .
APPLIED PHYSICS LETTERS, 1995, 67 (21) :3180-3182
[3]  
JONES EC, IN PRESS APPL PHYS L
[4]   AC LOSSES OF SUPERCONDUCTING HIGH-T-C MULTIFILAMENT BI-2223 AG SHEATHED TAPES IN PERPENDICULAR MAGNETIC-FIELDS [J].
KWASNITZA, K ;
CLERC, S .
PHYSICA C, 1994, 233 (3-4) :423-435