Extent of Aortic Coverage and Incidence of Spinal Cord Ischemia After Thoracic Endovascular Aneurysm Repair

被引:202
作者
Feezor, Robert J.
Martin, Tomas D.
Hess, Philip J., Jr.
Daniels, Michael J.
Beaver, Thomas M.
Klodell, Charles T.
Lee, W. Anthony [1 ]
机构
[1] Univ Florida, Div Vasc Surg & Endovasc Therapy, Dept Surg, Gainesville, FL 32610 USA
关键词
D O I
10.1016/j.athoracsur.2008.09.022
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background. Risk factors for spinal cord ischemia (SCI) after thoracic endovascular aneurysm repair (TEVAR) remain unclear. Aortic coverage was examined as a risk factor for SCI using quantitative three-dimensional computed tomography angiography (CTA) analysis. Methods. The medical records, radiographic imaging studies, and a prospectively maintained database of all TEVAR procedures performed during a 7-year period were retrospectively reviewed. Preoperative anatomic dimensions and postoperative graft path lengths were measured from CTAs using curved planar and orthogonal multiplanar reformations along centerline paths. SCI was defined as transient or permanent lower extremity neurologic deficit without associated intracerebral hemispheric events. Results. Of 326 TEVAR cases, 241 patients (74%) had satisfactory imaging. Thirty-three (10%) had SCI. These patients were older (72.7 +/- 10.6 vs 64.7 +/- 15.8 years, p = 0.005) and had longer intraoperative procedure times (137 +/- 65 vs 113 +/- 68 minutes, p = 0.05). Despite similar total lengths of native thoracic aorta (295.0 +/- 36.3 vs 283.1 +/- 39.8 mm, p = 0.17), patients with permanent SCI had a greater absolute (260.5 +/- 40.9 vs 195.8 +/- 81.6 mm, p = 0.002) and proportionate (88.8% +/- 12.1% vs 67.6% +/- 24.0%, p = 0.001) length of aortic coverage. The average length of uncovered aorta proximal to the celiac artery in patients with SCI was 17.3 +/- 21.8 mm vs 63.1 +/- 62.9 mm in patients without SCI (p = 0.0006). Neither the patency of the hypogastric arteries nor left subclavian artery was associated with SCI. Conclusions. The extent and distal location (relative to the celiac artery) of aortic coverage were associated with an increased risk of SCI. Prophylactic measures for spinal cord protection should be considered in patients whose thoracic aortas require extensive coverage.
引用
收藏
页码:1809 / 1814
页数:6
相关论文
共 11 条
[1]
Endovascular thoracic aortic repair and previous or concomitant abdominal aortic repair: Is the increased risk of spinal cord ischemia real? [J].
Baril, DT ;
Carroccio, A ;
Ellozy, SH ;
Palchik, E ;
Addis, MD ;
Jacobs, TS ;
Teodorescu, V ;
Marin, ML .
ANNALS OF VASCULAR SURGERY, 2006, 20 (02) :188-194
[2]
Endovascular stent grafting versus open surgical repair of descending thoracic aortic aneurysms in low-risk patients: A multicenter comparative trial [J].
Bavaria, Joseph E. ;
Appoo, Jehangir J. ;
Makaroun, Michel S. ;
Verter, Joel ;
Yu, Zi-Fan ;
Mitchell, R. Scott .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (02) :369-U17
[3]
Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. A study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) Registry [J].
Buth, Jacob ;
Harris, Peter L. ;
Hobo, Roel ;
van Eps, Randolph ;
Cuypers, Philippe ;
Duijm, Lucien ;
Tielbeek, Xander .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (06) :1103-1111
[4]
Strategies to manage paraplegia risk after endovascular stent repair of descending thoracic aortic aneurysms [J].
Cheung, AT ;
Pochettino, A ;
McGarvey, ML ;
Appoo, JJ ;
Fairman, RM ;
Carpenter, JP ;
Moser, WG ;
Woo, EY ;
Bavaria, JE .
ANNALS OF THORACIC SURGERY, 2005, 80 (04) :1280-1289
[5]
Risk of spinal cord ischemia after endograft repair of thoracic aortic aneurysms [J].
Gravereaux, EC ;
Faries, PL ;
Burks, JA ;
Latessa, V ;
Spielvogel, D ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (06) :997-1001
[6]
Spinal cord perfusion and protection during descending thoracic and thoracoabdominal aortic surgery: The collateral network concept [J].
Griepp, Randall B. ;
Griepp, Eva B. .
ANNALS OF THORACIC SURGERY, 2007, 83 (02) :S865-S869
[7]
Risk factors of neurologic deficit after thoracic aortic endografting [J].
Khoynezhad, Ali ;
Donayre, Carlos E. ;
Bui, Hao ;
Kopchok, George E. ;
Walot, Irwin ;
White, Rodney A. .
ANNALS OF THORACIC SURGERY, 2007, 83 (02) :S882-S889
[8]
Lazorthes G, 1970, Bull Acad Natl Med, V154, P34
[9]
Endovascular treatment of thoracic aortic aneurysms: Results of the phase II multicenter trial of the GORE TAG thoracic endoprosthesis [J].
Makaroun, MS ;
Dillavou, ED ;
Kee, ST ;
Sicard, G ;
Chaikof, E ;
Bavaria, J ;
Williams, D ;
Cambria, RP ;
Mitchell, RS .
JOURNAL OF VASCULAR SURGERY, 2005, 41 (01) :1-8
[10]
Importance of extrasegmental vessels for spinal cord blood supply in a chronic porcine model [J].
Strauch, JT ;
Spielvogel, D ;
Lauten, A ;
Zhang, N ;
Shiang, H ;
Weisz, D ;
Bodian, CA ;
Griepp, RB .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 24 (05) :817-824