Evaluation of the three-time-point method for diagnosis of breast lesions in contrast-enhanced MR mammography

被引:33
作者
Hauth, EAM
Stockamp, C
Maderwald, S
Mühler, A
Kimmig, R
Jaeger, H
Barkhausen, J
Forsting, M
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Univ Hosp Essen, Dept Neuroradiol, D-45122 Essen, Germany
[3] 3TP LLC, White Plains, NY USA
[4] Univ Hosp Essen, Dept Gynecol, D-45122 Essen, Germany
[5] Marien Hosp Wesel, Dept Radiol Neuroradiol & Nucl Med, Wesel, Germany
关键词
breast MR; contrast enhancement kinetics; tissue characterization; computers; diagnostic aid;
D O I
10.1016/j.clinimag.2005.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the three-time-point (3TP) method for diagnosis of breast lesions detected on contrast-enhanced MR mammography. Materials and Methods: MR imaging was performed in 40 women with 120 suspected breast lesions in mammography and/or sonography. The contrast kinetics was converted by 3TP software on a pixel-by-pixel basis into color-coded images. Lesion diagnosis was made by analysis of color intensity and color hue. The 3TP results were compared with the results of the region-of-interest (ROI) method. In 16 patients, we were able to correlate the results with histopathological findings. Results: The 3TP method could successfully be performed in all MR mammographies. Forty (33%) lesions had a diameter of less than 5 mm, 56 (47%) lesions between 5 and 10 mm, and 24 (20%) lesions were greater than 1 cm. Of all 120 lesions, 65 (54%) showed heterogeneous contrast enhancement. In 117 (97%) of all 120 lesions the results of ROI and the automated 3TP method were considered equivalent. However, in three lesions the manual ROI differed from the 3TP method. After a second, repeated manual ROI placement, we were able to confirm equivalent results with the 3TP images as well. Conclusions: The 3TP method automatically and reliably converts contrast kinetic information of the entire breast into a color-coded image. The 3TP method presents kinetic information of the entire dynamic series in an easy-to-interpret format and this automated method may allow to forego time-consuming and sometimes subjective manual ROI placements. This method displays the heterogeneity of the contrast enhancement pattern often observed in malignant lesions and makes it usable as diagnostic criterion. (C) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 15 条
[1]  
DEGANI H, 1997, NAT MED, V1, P207
[2]   Prognostic value of contrast-enhanced MR mammography in patients with breast cancer [J].
Fischer, U ;
Kopka, L ;
Brinck, U ;
Korabiowska, M ;
Schauer, A ;
Grabbe, E .
EUROPEAN RADIOLOGY, 1997, 7 (07) :1002-1005
[3]   SIGNAL TIME-RELATION OF BENIGN AND MALIGNANT LESIONS IN DYNAMIC 2D-MR IMAGING OF THE BREAST [J].
FISCHER, U ;
VONHEYDEN, D ;
VOSSHENRICH, R ;
VIEWEG, I ;
GRABBE, E .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (04) :287-292
[4]   Parametric analysis of breast MRI [J].
Furman-Haran, E ;
Degani, H .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (03) :376-386
[5]   Critical role of spatial resolution in dynamic contrast-enhanced breast MRI [J].
Furman-Haran, E ;
Grobgeld, D ;
Kelcz, F ;
Degani, H .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) :862-867
[6]  
Furman-Haran E, 1998, CLIN CANCER RES, V4, P2299
[7]   ASSESSMENT OF BREAST-CANCER RECURRENCE WITH CONTRAST-ENHANCED SUBTRACTION MR-IMAGING - PRELIMINARY-RESULTS IN 26 PATIENTS [J].
GILLES, R ;
GUINEBRETIERE, JM ;
SHAPEERO, LG ;
LESNIK, A ;
CONTESSO, G ;
SARRAZIN, D ;
MASSELOT, J ;
VANEL, D .
RADIOLOGY, 1993, 188 (02) :473-478
[8]  
HEYWANG SH, 1987, EUR J RADIOL, V7, P175
[9]   Application of a quantitative model to differentiate benign from malignant breast lesions detected by dynamic, gadolinium-enhanced MRI [J].
Kelcz, F ;
Santyr, GE ;
Cron, GO ;
Mongin, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05) :743-752
[10]   Clinical testing of high-spatial-resolution parametric contrast-enhanced MR imaging of the breast [J].
Kelcz, F ;
Furman-Haran, E ;
Grobgeld, D ;
Degani, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) :1485-1492