The potential for catheter microbial contamination from a needleless connector

被引:32
作者
Brown, JD
Moss, HA
Elliott, TSJ
机构
[1] Department of Clinical Microbiology, Queen Elizabeth Hospital, Edgbaston
关键词
microbial contamination; needleless connectors; S-epidermidis;
D O I
10.1016/S0195-6701(97)90193-6
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Needleless connectors have been widely introduced into clinical practice to allow the connection of syringes and luers to peripheral and central vascular catheters. The potential for microbial contamination of catheters via these devices is currently unclear. A recently introduced connector, the 'Connecta Clave', was assessed by various in-vitro methods. The 'Connecta Clave' is specifically devised to separate external components from the fluid pathway. The compression seals of 50 devices were contaminated with 1 x 10(4) cfu Staphylococcus epidermidis, disinfected with isopropanol, and fluid passed through. Only one device allowed organisms to pass through, despite this challenge, representing a contamination rate of 2%. In comparison, when 50 connectors were challenged with 20 cfu of S. epidermidis, no organisms passed through the device during use. In the clinical situation, after manipulation, <16 cfu of skin organisms were found associated with the compression seal of the devices. It is, therefore, likely that the contamination rates in clinical practice will be extremely low. Three methods of disinfecting the compression seals and associated rims were also evaluated. A combination of alcohol chlorhexidine spray, followed by a 70% isopropanol swab, resulted in the most efficacious disinfection. The isopropanol swabs produced an adequate disinfection rate. The overall results suggest that by use of specially designed connectors, not only are needlestick injuries reduced, but the likelihood of microbial contamination of catheters via the internal route may also be diminished.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 6 条
[1]   COMPARISON OF A NEEDLELESS SYSTEM WITH CONVENTIONAL HEPARIN LOCKS [J].
ADAMS, KS ;
ZEHRER, CL ;
THOMAS, W .
AMERICAN JOURNAL OF INFECTION CONTROL, 1993, 21 (05) :263-269
[2]   BLOOD-STREAM INFECTIONS ASSOCIATED WITH A NEEDLELESS INTRAVENOUS-INFUSION SYSTEM IN PATIENTS RECEIVING HOME INFUSION THERAPY [J].
DANZIG, LE ;
SHORT, LJ ;
COLLINS, K ;
MAHONEY, W ;
SEPE, S ;
BLAND, L ;
JARVIS, WR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 273 (23) :1862-1864
[3]   INTRAVASCULAR-DEVICE INFECTIONS [J].
ELLIOTT, TSJ .
JOURNAL OF MEDICAL MICROBIOLOGY, 1988, 27 (03) :161-167
[4]  
ELLIOTT TSJ, 1993, BRIT J HOSP MED, V48, P496
[5]   Microbial contamination of intravenous and arterial catheters [J].
Tebbs, SE ;
Elliott, TSJ ;
Ghose, A .
INTENSIVE CARE MEDICINE, 1996, 22 (03) :272-273
[6]   EFFICACY AND COST-EFFECTIVENESS OF A NEEDLELESS INTRAVENOUS ACCESS SYSTEM [J].
YASSI, A ;
MCGILL, ML ;
KHOKHAR, JB .
AMERICAN JOURNAL OF INFECTION CONTROL, 1995, 23 (02) :57-64