The measurement of the variation in the surface strains of Achilles tendon grafts using imaging techniques

被引:20
作者
DeFrate, LE
van der Ven, A
Boyer, PJ
Gill, TJ
Li, GA
机构
[1] Massachusetts Gen Hosp, Dept Orthopaed Surg, Bioengn Lab, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] MIT, Dept Mech Engn, Cambridge, MA USA
[4] Tufts Univ, Sch Med, Boston, MA USA
关键词
soft tissue; biomechanics; tensile testing; material properties; tendon; ligament;
D O I
10.1016/j.jbiomech.2004.12.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The purpose of this study was to use imaging techniques to measure the strains around the circumference of 11 mm wide Achilles tendon grafts during a uniaxial tensile test. Pairs of radiopaque beads with a diameter of 2 mm were affixed around the midsubstance of the tendon in four different locations. The motion of the beads was recorded using a cine fluoroscope. This system was shown to measure the displacement of the beads with an accuracy of 0.02 mm. During the uniaxial tensile test, large variations in local tissue strains were observed. At 10 MPa of applied stress, the local tissue strain varied from an average of 2.5-8.7%, an increase in strain of more than three times. As a result of these large variations, the modulus calculated from the stress-strain data varied from an average of 217 to 897 MPa, an increase of approximately 4 times. Furthermore, these data suggest that underestimates of the elastic modulus may result if a uniform strain distribution is assumed. These results indicate that during uniaxial tensile tests, the assumption of uniform stress and strain distributions should be carefully considered and small, uniform specimens should be used when measuring the material properties of soft tissues. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 28 条
[1]
An evaluation of the quasi-linear viscoelastic properties of the healing medial collateral ligament in a goat model [J].
Abramowitch, SD ;
Woo, SLY ;
Clineff, TD ;
Debski, RE .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (03) :329-335
[2]
The tensile and stress relaxation responses of human patellar tendon varies with specimen cross-sectional area [J].
Atkinson, TS ;
Ewers, BJ ;
Haut, RC .
JOURNAL OF BIOMECHANICS, 1999, 32 (09) :907-914
[3]
Basso O, 2002, CLIN ORTHOP RELAT R, P246
[4]
THE EFFECTS OF DONOR AGE AND STRAIN-RATE ON THE BIOMECHANICAL PROPERTIES OF BONE-PATELLAR TENDON-BONE ALLOGRAFTS [J].
BLEVINS, FT ;
HECKER, AT ;
BIGLER, GT ;
BOLAND, AL ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :328-333
[5]
EFFECTS OF STRUCTURE AND STRAIN-MEASUREMENT TECHNIQUE ON THE MATERIAL PROPERTIES OF YOUNG HUMAN TENDONS AND FASCIA [J].
BUTLER, DL ;
GROOD, ES ;
NOYES, FR ;
ZERNICKE, RF ;
BRACKETT, K .
JOURNAL OF BIOMECHANICS, 1984, 17 (08) :579-596
[6]
COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS [J].
BUTLER, DL ;
KAY, MD ;
STOUFFER, DC .
JOURNAL OF BIOMECHANICS, 1986, 19 (06) :425-432
[7]
[8]
MECHANICAL-PROPERTIES OF PRIMATE VASCULARIZED VS NONVASCULARIZED PATELLAR TENDON GRAFTS - CHANGES OVER TIME [J].
BUTLER, DL ;
GROOD, ES ;
NOYES, FR ;
OLMSTEAD, ML ;
HOHN, RB ;
ARNOCZKY, SP ;
SIEGEL, MG .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (01) :68-79
[9]
The effect of length on the structural properties of an achilles tendon graft as used in posterior cruciate ligament reconstruction [J].
DeFrate, LE ;
van der Ven, A ;
Gill, TJ ;
Li, GA .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (04) :993-997
[10]
A biomechanical evaluation of anterior and posterior tibialis tendons as suitable single-loop anterior cruciate ligament grafts [J].
Donahue, TLH ;
Howell, SM ;
Hull, ML ;
Gregersen, C .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (06) :589-597