Comparison of two ICP-MS set-ups for measuring 99Tc in large volume water samples

被引:26
作者
Keith-Roach, MJ
Stürup, S
Oughton, DH
Dahlgaard, H
机构
[1] Riso Natl Lab, Dept Nucl Safety Res, DK-4000 Roskilde, Denmark
[2] Riso Natl Lab, Dept Plant Biol & Biogeochem, DK-4000 Roskilde, Denmark
[3] Agr Univ Norway, Dept Chem & Biotechnol, N-1432 As, Norway
关键词
D O I
10.1039/b105708c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Large volume fjord and seawater samples have been radiochemically prepared for ICP-MS analysis in order to test the robustness of the procedure and to carry out a comparison of two ICP-MS set-ups. A sector field instrument (MicroMass PT2) Coupled with an ultrasonic nebuliser and a quadrupole ICP-MS (Perkin-Elmer Elan 6000) coupled with an electrothermal vaporisation (ETV) unit were used. The results showed that the radiochemical procedure was robust, removing Ru and Mo to acceptable levels, and that the two set-ups gave results that were in agreement. The correlation coefficient between the sets of 11 results was 1.0+/-0.05. The importance of establishing the matrix effect when using an ETV is discussed.
引用
收藏
页码:70 / 75
页数:6
相关论文
共 14 条
[1]   Determination of technetium-99 in aqueous samples by isotope dilution inductively coupled plasma-mass spectrometry [J].
Beals, DM .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1996, 204 (02) :253-263
[2]   Application of double-focusing sector field ICP mass spectrometry with shielded torch using different nebulizers for ultratrace and precise isotope analysis of long-lived radionuclides - Invited lecture [J].
Becker, JS ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1493-1500
[3]   Technetium measurements by accelerator mass spectrometry at LLNL [J].
Bergquist, BA ;
Marchetti, AA ;
Martinelli, RE ;
McAninch, JE ;
Nimz, GJ ;
Proctor, ID ;
Southon, JR ;
Vogel, JS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 172 :328-332
[4]   DETERMINATION OF TC-99 IN SEA-WATER AT ULTRA-LOW LEVELS [J].
CHEN, QJ ;
DAHLGAARD, H ;
NIELSEN, SP .
ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) :177-180
[5]   Analysis of naturally produced technetium and plutonium in geologic materials [J].
Dixon, P ;
Curtis, DB ;
Musgrave, J ;
Roensch, F ;
Roach, J ;
Rokop, D .
ANALYTICAL CHEMISTRY, 1997, 69 (09) :1692-1699
[6]   Accelerator mass spectrometry of 99Tc [J].
Fifield, LK ;
Carling, RS ;
Cresswell, RG ;
Hausladen, PA ;
di Tada, ML ;
Day, JP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 168 (03) :427-436
[7]   The use of 99mTc as a tracer in the determination of 99Tc by ICP-mass spectrometry [J].
Más, JL ;
Garcia-León, M ;
Bolívar, JP ;
Sánchez-Angulo, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1369-1373
[8]  
Montaser A, 1998, INDUCTIVELY COUPLED PLASMAS MASS SPECTROMETRY, P83
[9]   Determination of technetium-99 in aqueous solutions by inductively coupled plasma mass spectrometry: Effects of chemical form and memory [J].
Richter, RC ;
Koirtyohann, SR ;
Jurisson, SS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (05) :557-562
[10]  
SKIPPERUD LS, UNPUB J ANAL AT SPEC