Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams

被引:77
作者
Clift, MA [1 ]
Sutton, RA
Webb, DV
机构
[1] Royal Melbourne Inst Technol, Dept Appl Phys, Melbourne, Vic 3001, Australia
[2] Australian Radiat Protect & Nucl Safety Agcy, Melbourne, Vic 3085, Australia
关键词
D O I
10.1088/0031-9155/45/5/307
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
An organic scintillator detector system has been developed for radiotherapy bremsstrahlung dosimetry. The scintillators are connected to photodiodes by light pipes as the photodiodes must be removed and shielded from the incident radiation. The photodiodes see visible and near-visible light emissions from the scintillator as well as Cerenkov and fluorescence radiation that has been generated and trapped in the scintillator and light pipe. The Cerenkov and fluorescence radiation limits the accuracy of the dosimeter. This work examines a range of methods for diminishing the signal contribution of Cerenkov and fluorescence radiation while optimizing the scintillator signal. Three methods of achieving these goals have been used. They are: reflective coatings on the scintillator, long-wavelength-emitting scintillators used in conjunction with the photodiode, and absorptive filters placed between the light guide and photodiode. The contribution of the Cerenkov radiation to the light seen by the photodiode has been modelled and the model predictions have been tested using bremsstrahlung beams of peak energy between 13 and 20 MV, showing agreement with measurement.
引用
收藏
页码:1165 / 1182
页数:18
相关论文
共 16 条
[1]
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[2]
WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[3]
WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[4]
A NEW SCINTILLATOR DETECTOR SYSTEM FOR THE QUALITY ASSURANCE OF CO-60 AND HIGH-ENERGY THERAPY MACHINES [J].
BEDDAR, AS .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (02) :253-263
[5]
CERENKOV LIGHT GENERATED IN OPTICAL FIBERS AND OTHER LIGHT PIPES IRRADIATED BY ELECTRON-BEAMS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :925-935
[6]
Beddar AS., 1989, MED PHYS, V16, P683
[7]
BOER SF, 1993, PHYS MED BIOL, V38, P945
[8]
RESPONSE OF ORGANIC SCINTILLATORS TO ELECTRON ENERGY DEPOSITED IN THEM [J].
BRANNEN, E ;
OLDE, GL .
RADIATION RESEARCH, 1962, 16 (01) :1-&
[9]
RESPONSE OF ANTHRACENE AND STILBENE TO LOW-ENERGY PROTONS AND X-RAYS [J].
FOWLER, JM ;
ROOS, CE .
PHYSICAL REVIEW, 1955, 98 (04) :996-999
[10]
IAEA, 1987, IAEA TECHN REP SER, V277