This paper reports on a study concerning the development of a biochemical sensor for Staphylococcal Enterotoxin B (SEB), a substance within the bracket of biological warfare. A 20 MHz piezoelectric quartz crystal sensor device was employed in a flow injection system. The assay for SEB is based on a competition scheme using polyclonal antibodies (anti-SEB). Three parameters, i.e. the flow rate in the flow cell, the incubation time and the anti-SEB concentration, were optimized. A detection limit of 0.1 mu g/ml was obtained, whereas at concentrations of SEB of 10 mu g/ml or higher the sensor response was completely inhibited. The results were compared with a competition enzyme linked immunosorbent assay. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 16 条
[1]   HIV SEROLOGY USING PIEZOELECTRIC IMMUNOSENSORS [J].
ABERL, F ;
WOLF, H ;
KOSSLINGER, C ;
DROST, S ;
WOIAS, P ;
KOCH, S .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 18 (1-3) :271-275
[2]  
*BUTL TANN LTD, 1995, JAN NBC PROT EQ
[3]  
CARTER RM, 1995, ANAL LETT, V28, P1379
[4]   QUARTZ-CRYSTAL MICROBALANCE DETECTION OF VIBRIO-CHOLERAE O139 SEROTYPE [J].
CARTER, RM ;
MEKALANOS, JJ ;
JACOBS, MB ;
LUBRANO, GJ ;
GUILBAULT, GG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 187 (01) :121-125
[5]   APPLICATION POTENTIAL OF LIQUID-PHASE ACOUSTIC-WAVE DEVICES AS CHEMICAL AND BIOCHEMICAL SENSORS [J].
CAVICVLASAK, BA ;
RAJAKOVIC, LJV .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (04) :339-347
[6]  
Curie J., 1880, Bull. La Socit Minralogique Fr, V3, P90, DOI [10.3406/bulmi.1880.1564, DOI 10.3406/BULMI.1880.1564]
[7]   BACTERIAL TOXINS - A TABLE OF LETHAL AMOUNTS [J].
GILL, DM .
MICROBIOLOGICAL REVIEWS, 1982, 46 (01) :86-94
[8]   ACOUSTIC-WAVE MICROSENSORS .1. [J].
GRATE, JW ;
MARTIN, SJ ;
WHITE, RM .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :A940-A948
[9]   RAPID DETECTION OF ESCHERICHIA-COLI USING A SEPARATED ELECTRODE PIEZOELECTRIC CRYSTAL SENSOR [J].
HE, FJ ;
GENG, Q ;
ZHU, WH ;
NIE, LH ;
YAO, SZ ;
MEIFENG, C .
ANALYTICA CHIMICA ACTA, 1994, 289 (03) :313-319
[10]   RAPID DETECTION OF STAPHYLOCOCCUS-AUREUS USING A SEPARATED ELECTRODE PIEZOELECTRIC CRYSTAL SENSOR [J].
HE, FJ ;
DENG, L ;
XIE, QJ ;
NIE, LH ;
YAO, SH .
ANALYTICAL LETTERS, 1995, 28 (02) :213-224