Speech understanding in quiet and in noise with the CIS speech coding strategy (MED-EL Combi-40) compared to the multipeak and spectral peak strategies (Nucleus)

被引:51
作者
Kiefer, J
Muller, J
Pfennigdorff, T
Schon, F
Helms, J
vonIlberg, C
Baumgartner, W
Gstottner, W
Ehrenberger, K
Arnold, W
Stephan, K
Thumfart, W
Baur, S
机构
来源
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES | 1996年 / 58卷 / 03期
关键词
Cochlear implant; speech understanding; speech coding; continuous interleaved sampling; multipeak speech coding; spectral-peak speech coding;
D O I
10.1159/000276812
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
This study compares sentence understanding in quiet and in noise with 3 different speech coding strategies for cochlear implants. The results show that the spectral-peak (SPEAK) and continuous-interleaved-sampling (CIS) coding strategies, based on spectral signal analysis, allow for better speech understanding in quiet as well as in noise, than the multipeak (MPEAK) coding strategy, which relys on speech feature extraction. In the intrasubject comparison of the MPEAK and SPEAK strategies, the SPEAK coding strategy provided a considerable improvement in quiet and in noise for the majority of patients using the Nucleus 22 Mini-implant. In the intersubject comparisons, the mean results in noise with the CIS strategy were superior to both the MPEAK and the SPEAK strategies. The difference was greatest for the most difficult tests in noise. Understanding in noise was least reduced for the CIS strategy. Understanding in quiet was not significantly different between the CIS and the SPEAK strategies; both strategies were significantly better than the MPEAK strategy in quiet. These results are still preliminary, due to the relatively small number of patients and the great inherent intersubject variability of results.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 17 条
[1]  
BATTMER RD, 1995, 3 PAR INT COCHL IMPL, P330
[2]  
DILLIER N, 1995, AUDIOLOGY, V34, P145
[3]   SPEECH-PERCEPTION USING A 2-FORMANT 22-ELECTRODE COCHLEAR PROSTHESIS IN QUIET AND IN NOISE [J].
DOWELL, RC ;
SELIGMAN, PM ;
BLAMEY, PJ ;
CLARK, GM .
ACTA OTO-LARYNGOLOGICA, 1987, 104 (5-6) :439-446
[4]  
DOWELL RC, 1984, ACTA OTOLARYNGOL S S, V144, P230
[5]  
HARTMANN R, 1989, COCHLEAR IMPLANTS MO, P135
[6]  
JAVEL E, 1989, COCHLEAR IMPLANTS MO, P247
[7]  
LAWSON DT, 1993, PROG BRAIN RES, V97, P313
[8]   A NEW PORTABLE SOUND PROCESSOR FOR THE UNIVERSITY-OF-MELBOURNE NUCLEUS LIMITED MULTIELECTRODE COCHLEAR IMPLANT [J].
MCDERMOTT, HJ ;
MCKAY, CM ;
VANDALI, AE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (06) :3367-3371
[9]  
Mckay C.M., 1991, J OTOLARYNGOL SOC AU, V6, P354
[10]   PERCEPTUAL PERFORMANCE OF SUBJECTS WITH COCHLEAR IMPLANTS USING THE SPECTRAL MAXIMA SOUND PROCESSOR (SMSP) AND THE MINI SPEECH PROCESSOR (MSP) [J].
MCKAY, CM ;
MCDERMOTT, HJ .
EAR AND HEARING, 1993, 14 (05) :350-367