Microdosimetric properties of ionizing electrons in water: a test of the PENELOPE code system

被引:62
作者
Stewart, RD [1 ]
Wilson, WE
McDonald, JC
Strom, DJ
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
[2] Washington State Univ Tri Cities, Richland, WA 99352 USA
关键词
D O I
10.1088/0031-9155/47/1/306
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ability to simulate the tortuous path of very low-energy electrons in condensed matter is important for a variety of applications in radiobiology. Event-by-event Monte Carlo codes such as OREC, MOCA and PITS represent the preferred method of computing distributions of microdosimetric quantities. However, event-by-event Monte Carlo is computationally expensive, and the cross sections needed to transport simulations to this level of detail are usually only available for water. In the recently developed PENELOPE code system, 'hard' electron and positron interactions are simulated in a detailed way while,'soft' interactions are treated using multiple scattering theory. Using this mixed simulation algorithm, electrons and positrons can be transported down to energies as low as 100eV. To our knowledge, PENELOPE is the first widely available, general purpose Monte Carlo code system capable of transporting electrons and positrons in arbitrary media down to such low energies. The ability to transport electrons and positrons to such low energies opens up the possibility of using a general purpose Monte Carlo code system for microdosimetry. This paper presents the results of a code intercomparison study designed to test the applicability of the PENELOPE code system for microdosimetry applications. For sites comparable in size to a mammalian cell or cell nucleus, single-event distributions, site-hit probabilities and the frequency-mean specific energy per event are in reasonable agreement with those predicted using event-by-event Monte Carlo. Site-hit probabilities and the mean specific energy per event can be estimated to within about 1-10% of those predicted using event-by-event Monte Carlo. However, for some combinations of site size and source-target geometry, site-hit probabilities and the mean specific energy per event may only agree to within 25-60%. The most problematic source-target geometry is one in which the emitted electrons are very close to the tally site (e.g., a point source on the surface of it cell). Although event-by-event Monte Carlo will continue to be the method of choice for microdosimetry, PENELOPE is a useful, computationally efficient tool for some classes of microdosimetry problem. PENELOPE may prove particularly Useful for applications that involve radiation transport through materials other than water or for applications that are too computationally intensive for event-by-event Monte Carlo, such as in vivo microdosimetry of spatially complex distributions Of radioisotopes inside the human body.
引用
收藏
页码:79 / 88
页数:10
相关论文
共 37 条
[1]  
[Anonymous], 1988, MONTE CARLO TRANSPOR, DOI DOI 10.1007/978-1-4613-1059-4_2
[2]   PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER [J].
BARO, J ;
SEMPAU, J ;
FERNANDEZVAREA, JM ;
SALVAT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) :31-46
[3]  
BERGER MJ, 1976, 73107 NBSIR
[4]  
BOLCH WE, 1994, RADIAT PROT DOSIM, V52, P77
[5]  
Brenner DJ, 2001, RADIAT RES, V155, P402, DOI 10.1667/0033-7587(2001)155[0402:TBEIRO]2.0.CO
[6]  
2
[7]  
Briesmeister J.F, 1997, MCNP GEN MONTE CARLO
[8]  
Halbleib J. A., 1992, ITS VERSION 3 0 INTE
[9]  
International Commission of Radiation Units and Measurements (ICRU), 1983, 36 ICRU
[10]  
Lewis DA, 2001, RADIAT RES, V156, P251, DOI 10.1667/0033-7587(2001)156[0251:PODDAN]2.0.CO