The use of advanced mapping systems to guide right linear lesions in paroxysmal atrial fibrillation

被引:2
作者
Gasparini, M [1 ]
Mantica, M [1 ]
Coltorti, F [1 ]
Galimberti, P [1 ]
Ceriotti, C [1 ]
机构
[1] Ist Clin Humanitas, Electrophysiol & Pacing Unit, I-20089 Milan, Italy
关键词
atrial fibrillation; mapping; radiofrequency linear ablation;
D O I
10.1016/S1520-765X(01)90071-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Right atrial linear ablation has been used for the treatment of refractory atrial fibrillation (AF), with conflicting results. Conventional mapping techniques that have thus far been used for this purpose have resulted in lengthy procedure times and radiation exposure. while proving unsatisfactory in verifying the completeness of block lines. Alternative advanced three, dimensional non-fluoroscopic mapping systems that have recently been introduced may prove to be advantageous in transcatheter linear ablation to cure AF. This is because of their ability to improve the accuracy of ablation, to provide a highly detailed analysis of the atrial activation pattern once linear lesions have been created, and to reduce X-ray exposure time. Notwithstanding the lack of information on long-term follow up, the treatment of idiopathic drug-resistant AF using right atrial linear ablation guided by an advanced mapping system is, in our experience, both feasible and safe; a desirable clinical Outcome may be achieved in more than two-thirds of patients, with some patients experiencing complete abolition of AF and others a statistically significant reduction in the number of symptomatic AF episodes. The use of advanced mapping systems in conjunction with atrial pacing on both sides of the tines of ablation is essential in order to assess completeness of the bidirectional block. Because procedural risks are very low, a first-step approach employing right atrial compartmentalization appears justified in selected patients with drug-refractory AF, who exhibit no evidence of focal substrates from which AF might initiate. (C) 2001 The European Society of Cardiology.
引用
收藏
页码:P41 / P46
页数:6
相关论文
共 29 条
[1]  
Allesie MA, 1990, CARDIAC ELECTROPHYSI, P548
[2]  
AVITALL B, 1994, J AM COLL CARDIOL, V24, pA276
[3]   5-YEAR EXPERIENCE WITH THE MAZE PROCEDURE FOR ATRIAL-FIBRILLATION [J].
COX, JL ;
BOINEAU, JP ;
SCHUESSLER, RB ;
KATER, KM ;
LAPPAS, DG ;
GOTT, VL ;
CRAWFORD, FA .
ANNALS OF THORACIC SURGERY, 1993, 56 (04) :814-824
[4]   Modification of the substrate for maintenance of idiopathic human atrial fibrillation -: Efficacy of radiofrequency ablation using nonfluoroscopic catheter guidance [J].
Ernst, S ;
Schlüter, M ;
Ouyang, F ;
Khanedani, A ;
Cappato, R ;
Hebe, J ;
Volkmer, M ;
Antz, M ;
Kuck, KH .
CIRCULATION, 1999, 100 (20) :2085-2092
[5]  
Feld GK, 1997, J AM COLL CARDIOL, V29, P7751
[6]   Atrial mapping and radiofrequency catheter ablation inpatients with idiopathic atrial fibrillation -: Electrophysiological findings and ablation results [J].
Gaita, F ;
Riccardi, R ;
Calò, L ;
Scaglione, M ;
Garberoglio, L ;
Antolini, R ;
Kirchner, M ;
Lamberti, F ;
Richiardi, E .
CIRCULATION, 1998, 97 (21) :2136-2145
[7]   Right atrial compartmentalization using radiofrequency catheter ablation for management of patients with refractory atrial fibrillation [J].
Garg, A ;
Finneran, W ;
Mollerus, M ;
Birgersdotter-Green, U ;
Fujimura, O ;
Tone, L ;
Feld, GK .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (06) :763-771
[8]  
Gasparini M, 2000, PACE, V23, P1843
[9]   Atrial linear ablations in pigs - Chronic effects on atrial electrophysiology and pathology [J].
Gepstein, L ;
Hayam, G ;
Shpun, S ;
Cohen, D ;
Ben-Haim, SA .
CIRCULATION, 1999, 100 (04) :419-426
[10]   Right and left atrial radiofrequency catheter therapy of paroxysmal atrial fibrillation [J].
Haissaguerre, M ;
Jais, P ;
Shah, DC ;
Gencel, L ;
Pradeau, V ;
Garrigues, S ;
Chouairi, S ;
Hocini, M ;
LeMetayer, P ;
Roudaut, R ;
Clementy, J .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (12) :1132-1144