Percutaneous aortic valve replacement using a W-model valved stent: a preliminary feasibility study in sheep

被引:6
作者
Bai Yuan [1 ]
Zong Gang-jun [3 ]
Wang Yan-yan [4 ]
Jiang Hai-bin [1 ]
Li Wei-ping [2 ]
Wu Hong [1 ]
Zhao Xian-xian [1 ]
Qin Yong-wen [1 ]
机构
[1] Second Mil Med Univ, Dept Cardiol, Changhai Hosp, Shanghai 200433, Peoples R China
[2] Second Mil Med Univ, Dept Ultrasonog, Changhai Hosp, Shanghai 200433, Peoples R China
[3] 101 Hosp PLA, Dept Cardiol, Wuxi 210044, Jiangsu, Peoples R China
[4] Fudan Univ, Dept Internal Med, Zhongshan Hosp, Shanghai 200032, Peoples R China
关键词
percutaneous; aortic valve; valved stent; bioprosthesis; TRANSCATHETER IMPLANTATION; IN-VITRO; STENOSIS; PROSTHESIS; EXPERIENCE; SYSTEM; STEPS;
D O I
10.3760/cma.j.issn.0366-6999.2009.06.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Percutaneous aortic valve replacement is a promising strategy in the treatment of patients with aortic valve stenosis. And many kinds of valved stents have been implanted in selected patients worldwide. However, the clinical experience is still limited. We developed a W-model valved stent and evaluated the feasibility and safety of percutaneous implantation of the device in the native aortic valve position. Methods A self expanding nitinol stent with W-model, containing porcine pericardium valves in its proximal part, was implanted in six sheep by means of a 14 French catheter through the right common iliac artery under guidance of fluoroscopy. During stent deployment the original aortic valve was pushed against the aortic wall by the self expanding force of the stent while the new valve was expanded. These sheep were followed up shortly after procedure with supra-aortic angiogram and left ventriculography. Additionally, one sheep was sacrificed after the procedure for anatomic evaluation. Results It was possible to replace the aortic valve in the beating heart in four sheep. The procedure failed in two sheep due to coronary orifice occlusion in one case and severe aortic valve regurgitation in the other case. One sheep was killed one hour after percutaneous aortic valve replacement for anatomic evaluation. There were no signs of damage of the aortic intima, or of obstruction of the coronary orifice. Conclusions Percutaneous aortic valve replacement with a W-model valved stent in the beating heart is possible. Further studies are mandatory to assess safety and efficacy of this kind of valved stent in larger sample size and by longer follow-up period.
引用
收藏
页码:655 / 658
页数:4
相关论文
共 20 条
[1]   TRANSLUMINAL IMPLANTATION OF ARTIFICIAL-HEART VALVES - DESCRIPTION OF A NEW EXPANDABLE AORTIC-VALVE AND INITIAL RESULTS WITH IMPLANTATION BY CATHETER TECHNIQUE IN CLOSED CHEST PIGS [J].
ANDERSEN, HR ;
KNUDSEN, LL ;
HASENKAM, JM .
EUROPEAN HEART JOURNAL, 1992, 13 (05) :704-708
[2]   Percutaneous aortic valve implantation. The demise of classical aortic valve replacement? [J].
Antunes, Manuel J. .
EUROPEAN HEART JOURNAL, 2008, 29 (11) :1339-1341
[3]   Novel therapeutic aspects of percutaneous aortic valve replacement with the 21F CoreValve Revalving™ system [J].
Berry, Colin ;
Asgar, Anita ;
Lamarche, Yoan ;
Marcheix, Bertrand ;
Couture, Pierre ;
Basmadjian, Arsene ;
Ducharme, Anique ;
Laborde, Jean-Claude ;
Cartier, Raymond ;
Bonan, Raoul .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (04) :610-616
[4]   Percutaneous approaches to valvular heart disease [J].
Block P.C. ;
Bonhoeffer P. .
Current Cardiology Reports, 2005, 7 (2) :108-113
[5]   Steps toward the percutaneous replacement of atrioventricular valves - An experimental study [J].
Boudjemline, Y ;
Agnoletti, G ;
Bonnet, D ;
Behr, L ;
Borenstein, N ;
Sidi, D ;
Bonhoeffer, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) :360-365
[6]   Steps toward percutaneous aortic valve replacement [J].
Boudjemline, Y ;
Bonhoeffer, P .
CIRCULATION, 2002, 105 (06) :775-778
[7]   Percutaneous implantation of the first repositionable aortic valve prosthesis in a patient with severe aortic stenosis [J].
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Grube, Eberhard .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (05) :579-584
[8]   Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[9]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[10]   Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly [J].
Descoutures, Fleur ;
Himbert, Dominique ;
Lepage, Laurent ;
Iung, Bernard ;
Detaint, Delphine ;
Tchetche, Didier ;
Brochet, Eric ;
Castier, Yves ;
Depoix, Jean-Pol ;
Nataf, Patrick ;
Vahanian, Alec .
EUROPEAN HEART JOURNAL, 2008, 29 (11) :1410-1417