Impact of coronary artery remodeling on misinterpretation of angiographic disease eccentricity: evidence from intravascular ultrasound

被引:11
作者
Ito, K [1 ]
Yamagishi, M [1 ]
Yasumura, Y [1 ]
Nakatani, S [1 ]
Yasuda, S [1 ]
Miyatake, K [1 ]
机构
[1] Natl Cardiovasc Ctr, Cardiol Div Med, Osaka 5658565, Japan
关键词
eccentricity; remodeling; quantitative coronary angiography; intravascular ultrasound;
D O I
10.1016/S0167-5273(99)00092-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was designed to examine the impact of coronary artery remodeling, enlargement or shrinkage, on the angiographic disease eccentricity. A total of 82 coronary sites from 73 patients with significant stenosis (>50%) were prospectively analyzed by both quantitative coronary angiography and intravascular ultrasound. By quantitative coronary angiography, the maximal and minimal distances from the center of the stenosis to the outline of the vessel wall were measured, and the eccentricity index was calculated by the formula ((maximal-minimal)/maximal). By intravascular ultrasound, the maximal and minimal distances from the center of the lumen to the leading edge of the second echogenic zone were measured, and the eccentricity index was calculated by the same formula. For identifying the vessel remodeling, the total vessel area that was determined by tracing the leading edge of the second echogenic zone was measured at the stenotic sites and the adjacent proximal and distal segments. By quantitative coronary angiography, the maximal and minimal distances were 1.76+/-0.6 and 0.97+/-0.3 mm, respectively, yielding an eccentricity index of 0.42+/-0.2. The maximal and minimal distances by intravascular ultrasound were 2.77+/-0.6 mm and 1.46+/-0.4 mm, respectively, yielding an eccentricity index of 0.45+/-0.2 (NS). Although the average eccentricity index was not different between the two methods, there was substantially no correlation between the eccentricity index determined by the two methods (r=0.38, y = 0.43x + 0.22). However, this correlation was significantly improved (r = 0.55, y = 0.73x + 0.12, P <0.001) when 44 stenotic segments with remodeling were excluded for comparison. These results indicate that coronary artery remodeling could be a major contributing factor to angiographic misinterpretation of disease eccentricity. We suggest that intravascular ultrasound is a powerful method that can accurately determine diseases eccentricity as well as disease severity. (C) 1999 Elsevier Science Ireland Ltd. Al rights reserved.
引用
收藏
页码:275 / 282
页数:8
相关论文
共 17 条
[1]   Clinical application and image interpretation in intracoronary ultrasound [J].
Di Mario, C ;
Gorge, G ;
Peters, R ;
Kearney, P ;
Pinto, F ;
Hausmann, D ;
von Birgelen, C ;
Colombo, A ;
Mudra, H ;
Roelandt, J ;
Erbel, R .
EUROPEAN HEART JOURNAL, 1998, 19 (02) :207-229
[2]   INTIMAL HYPERPLASIA, VASCULAR MODELING, AND THE RESTENOSIS PROBLEM [J].
GLAGOV, S .
CIRCULATION, 1994, 89 (06) :2888-2891
[3]   COMPENSATORY ENLARGEMENT OF HUMAN ATHEROSCLEROTIC CORONARY-ARTERIES [J].
GLAGOV, S ;
WEISENBERG, E ;
ZARINS, CK ;
STANKUNAVICIUS, R ;
KOLETTIS, GJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (22) :1371-1375
[4]   CAN INTRACORONARY ULTRASOUND CORRECTLY ASSESS THE LUMINAL DIMENSIONS OF CORONARY-ARTERY LESIONS - A COMPARISON WITH QUANTITATIVE ANGIOGRAPHY [J].
HAASE, J ;
OZAKI, Y ;
DIMARIO, C ;
ESCANED, J ;
DEFEYTER, PJ ;
ROELANDT, JRTC ;
SERRUYS, PW .
EUROPEAN HEART JOURNAL, 1995, 16 (01) :112-119
[5]   INVIVO VALIDATION OF COMPENSATORY ENLARGEMENT OF ATHEROSCLEROTIC CORONARY-ARTERIES [J].
HERMILLER, JB ;
TENAGLIA, AN ;
KISSLO, KB ;
PHILLIPS, HR ;
BASHORE, TM ;
STACK, RS ;
DAVIDSON, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (08) :665-668
[6]   MORPHOLOGICAL EFFECTS OF CORONARY BALLOON ANGIOPLASTY INVIVO ASSESSED BY INTRAVASCULAR ULTRASOUND IMAGING [J].
HONYE, J ;
MAHON, DJ ;
JAIN, A ;
WHITE, CJ ;
RAMEE, SR ;
WALLIS, JB ;
ALZARKA, A ;
TOBIS, JM .
CIRCULATION, 1992, 85 (03) :1012-1025
[7]  
ITO K, 1999, JPN CIRC J S1, V63, P286
[8]  
Lim TT, 1997, CIRCULATION, V95, P855
[9]   AN EXPLANATION FOR DISCREPANCY BETWEEN ANGIOGRAPHIC AND INTRAVASCULAR ULTRASOUND MEASUREMENTS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
NAKAMURA, S ;
MAHON, DJ ;
MAHESWARAN, B ;
GUTFINGER, DE ;
COLOMBO, A ;
TOBIS, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (03) :633-639
[10]   Contribution of inadequate compensatory enlargement to development of human coronary artery stenosis: An in vivo intravascular ultrasound study [J].
Nishioka, T ;
Luo, H ;
Eigler, NL ;
Berglund, H ;
Kim, CJ ;
Siegel, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (07) :1571-1576