Robotic skeletonizing of the internal thoracic artery: Is it safe?

被引:14
作者
Bolotin, G [1 ]
Scott, WW [1 ]
Austin, TC [1 ]
Charland, PJ [1 ]
Kypson, AP [1 ]
Nifong, LW [1 ]
Salleng, K [1 ]
Chitwood, WR [1 ]
机构
[1] E Carolina Univ, Brody Sch Med, Div Cardiothorac Surg, Greenville, NC USA
关键词
D O I
10.1016/j.athoracsur.2003.09.074
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background. The advantages of internal thoracic artery skeletonization include early high blood flow, a longer conduit, and less bleeding than pedicle internal thoracic artery grafts. Longer conduits are needed for complete endoscopic arterial revascularization. Therefore this study was designed to determine the feasibility and safety of internal thoracic artery skeletonization using the da Vinci robotic system (Intuitive Surgical, Sunnyvale, CA). Methods. Nine dogs underwent bilateral robotic internal thoracic artery harvesting through three ports placed in the left chest. One internal thoracic artery was harvested as a pedicle in each dog, and the other was skeletonized. Internal thoracic artery blood flow was measured in each graft, and comparative endothelial histologic studies were performed. Data are mean +/- the standard error of the mean. Results. All 18 internal thoracic arteries were harvested successfully. Skeletonized internal thoracic artery harvests required more time (48.0 minutes +/- 1.8) than pedicle internal thoracic artery harvests (39.0 minutes +/- 1.4; p < 0.05). Internal thoracic artery flows during the final intervals were similar (skeletonized = 30.0 mL/min ± 2.4 vs pedicle = 31.5 mL/min ± 1.8; p = 0.9). Free internal thoracic artery bleeding flow was similar in both groups (skeletonized 162.0 mL/min ± 3.0 vs pedicle = 189.0 mL/min ± 2.4; p = 0.4). Histologically, both groups were similar with minimal endothelial damage. Conclusions. Robotically skeletonized harvesting is safe, but it requires more time (48.0 minutes ± 1.8) than pedicle internal thoracic artery harvesting. Despite muted tactile feedback with robotics, neither technique was associated with histologic or functional damage. These encouraging results may represent an advantage for complete arterial revascularization in robotic coronary bypass patients.
引用
收藏
页码:1262 / 1265
页数:4
相关论文
共 17 条
[1]
Early experience with robotic technology for coronary artery surgery [J].
Boehm, DH ;
Reichenspurner, H ;
Gulbins, H ;
Detter, C ;
Meiser, B ;
Brenner, F ;
Habazettl, H ;
Reichart, B .
ANNALS OF THORACIC SURGERY, 1999, 68 (04) :1542-1546
[2]
Bilateral internal mammary artery grafting: Midterm results of pedicled versus skeletonized conduits [J].
Calafiore, AM ;
Vitolla, G ;
Iaco, AL ;
Fino, C ;
Di Giammarco, G ;
Marchesani, F ;
Teodori, G ;
D'Addario, G ;
Mazzei, V .
ANNALS OF THORACIC SURGERY, 1999, 67 (06) :1637-1642
[3]
Changing pattern in beating heart operations: Use of skeletonized internal thoracic artery [J].
Cartier, R ;
Leacche, M ;
Couture, P .
ANNALS OF THORACIC SURGERY, 2002, 74 (05) :1548-1552
[4]
Intraoperative and laboratory evaluation of skeletonized versus pedicled internal thoracic artery [J].
Deja, MA ;
Wos, S ;
Golba, KS ;
Zurek, P ;
Domaradzki, W ;
Bachowski, R ;
Spyt, TJ .
ANNALS OF THORACIC SURGERY, 1999, 68 (06) :2164-2168
[5]
Effect of skeletonization of the internal thoracic artery on vessel wall integrity [J].
Gaudino, M ;
Toesca, A ;
Nori, SL ;
Glieca, F ;
Possati, G .
ANNALS OF THORACIC SURGERY, 1999, 68 (05) :1623-1627
[6]
Routine use of bilateral skeletonized internal mammary arteries for myocardial revascularization [J].
Gurevitch, J ;
Paz, Y ;
Shapira, I ;
Matsa, M ;
Kramer, A ;
Pevni, D ;
Lev-Ran, O ;
Moshkovitz, Y ;
Mohr, R .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :406-411
[7]
Jacobs S, 2001, HEART SURG FORUM, V4, P307
[8]
Technique of closed chest coronary artery surgery on the beating heart [J].
Kappert, U ;
Cichon, R ;
Schneider, J ;
Gulielmos, V ;
Ahmadzade, T ;
Nicolai, J ;
Tugtekin, SM ;
Schueler, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (04) :765-769
[9]
Kappert U, 2000, HEART SURG FORUM, V3, P319
[10]
THE SKELETONIZED INTERNAL MAMMARY ARTERY [J].
KEELEY, SB .
ANNALS OF THORACIC SURGERY, 1987, 44 (03) :324-325