Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients

被引:139
作者
Ichikawa, T
Haradome, H
Hachiya, J
Nitatori, T
Araki, T
机构
[1] Yamanashi Med Univ, Dept Radiol, 1110 Shimokato, Yamanashi 40938, Japan
[2] Kyorin Univ, Sch Med, Dept Radiol, Tokyo 181, Japan
来源
ABDOMINAL IMAGING | 1999年 / 24卷 / 05期
关键词
abdomen; magnetic resonance; liver; rapid imaging; diffusion study; echo planar;
D O I
10.1007/s002619900539
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: To determine the potential ability of diffusion-weighted magnetic resonance (MR) imaging with single-shot echo-planar imaging (DW imaging) in the upper abdomen by apparent diffusion coefficient (ADC) and signal:intensity ratio (SIR) measurements. Methods: DW imaging was performed in 61 clinical patients. ADCs in the liver, pancreas, spleen, kidney, and different pathological conditions were calculated. Spleen-to-liver SIR and segmental intensity difference of the liver (SID) were also calculated. Results: The mean ADCs (mm(2)/s) were 2.28 x 10(-3) +/- 0.07 in the liver, 1.44 x 10(-3) +/- 0.05 in the spleen, 1.94 x 10(-3) +/- 0.19 in the pancreas, and 5.76 x 10(-3) +/- 0.06 in the kidney. The mean ADC of cirrhotic liver was 1.96 x 10(-3) +/- 0.62, which was lower than that of normal liver. Other pathologic conditions also showed ADCs different from those of normal tissues. All DW images showed significantly higher spleen-to-liver SIRs and SIDs than did T2-weighted images (p < 0.05). Conclusion: The mean ADCs obtained with DW imaging were different in each upper abdominal organ and with each pathologic condition. DW images showed: better soft tissue contrast than did T2-weighted images with regard to SIR and CNR in depicting and characterizing upper abdominal disorders.
引用
收藏
页码:456 / 461
页数:6
相关论文
共 18 条
  • [1] REAL-TIME MOVIE IMAGING FROM A SINGLE CARDIAC CYCLE BY NMR
    CHAPMAN, B
    TURNER, R
    ORDIDGE, RJ
    DOYLE, M
    CAWLEY, M
    COXON, R
    GLOVER, P
    MANSFIELD, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) : 246 - 254
  • [2] IN-VIVO MEASUREMENT OF WATER DIFFUSION IN THE HUMAN HEART
    EDELMAN, RR
    GAA, JC
    WEDEEN, VJ
    LOH, E
    HARE, JM
    PRASAD, P
    LI, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 423 - 428
  • [3] IMPROVEMENTS IN SNAP-SHOT NUCLEAR MAGNETIC-RESONANCE IMAGING
    HOWSEMAN, AM
    STEHLING, MK
    CHAPMAN, B
    COXON, R
    TURNER, R
    ORDIDGE, RJ
    CAWLEY, MG
    GLOVER, P
    MANSFIELD, P
    COUPLAND, RE
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (729) : 822 - 828
  • [4] SEGMENTAL INTENSITY DIFFERENCES IN THE LIVER ON MR IMAGES - A SIGN OF INTRAHEPATIC PORTAL FLOW STOPPAGE
    ITAI, Y
    OHTOMO, K
    KOKUBO, T
    OKADA, Y
    YAMAUCHI, T
    YOSHIDA, H
    [J]. RADIOLOGY, 1988, 167 (01) : 17 - 19
  • [5] Le Bihan D, 1991, Magn Reson Q, V7, P1
  • [6] IMAGING OF DIFFUSION AND MICROCIRCULATION WITH GRADIENT SENSITIZATION - DESIGN, STRATEGY, AND SIGNIFICANCE
    LEBIHAN, D
    TURNER, R
    MOONEN, CTW
    PEKAR, J
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (01): : 7 - 28
  • [7] DIFFUSION-WEIGHTED MR IMAGING OF ANISOTROPIC WATER DIFFUSION IN CAT CENTRAL-NERVOUS-SYSTEM
    MOSELEY, ME
    COHEN, Y
    KUCHARCZYK, J
    MINTOROVITCH, J
    ASGARI, HS
    WENDLAND, MF
    TSURUDA, J
    NORMAN, D
    [J]. RADIOLOGY, 1990, 176 (02) : 439 - 445
  • [8] MOSELEY ME, 1990, AM J NEURORADIOL, V11, P423
  • [9] MULLER MF, 1994, RADIOLOGY, V190, P475
  • [10] MULLER MF, 1994, RADIOLOGY, V193, P711