Underuse of lung protective ventilation: Analysis of potential factors to explain physician behavior

被引:147
作者
Kalhan, R [1 ]
Mikkelsen, M
Dedhiya, P
Christie, J
Gaughan, C
Lanken, PN
Finkel, B
Gallop, R
Fuchs, BD
机构
[1] Northwestern Univ, Div Pulm & Crit Care, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Hosp Univ Penn, Dept Med, Philadelphia, PA 19104 USA
[3] Hosp Univ Penn, Div Pulm Allergy & Crit Care Med, Philadelphia, PA 19104 USA
[4] Univ Penn, Ctr Clin Epidemiol & Biostat, Philadelphia, PA 19104 USA
[5] W Chester Univ, Dept Math, Appl Stat Program, W Chester, PA 19380 USA
基金
美国国家卫生研究院;
关键词
acute respiratory distress syndrome; mechanical ventilation; tidal volumes; physician practice patterns;
D O I
10.1097/01.CCM.0000198328.83571.4A
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the frequency of use of low-tidal-volume ventilation in appropriate patients with acute lung injury (ALI) and the factors associated with the choice of tidal volume. Design: Prospective observational cohort study of patients identified with ALI or acute respiratory distress syndrome from September 2000 to November 2002. Setting. Medical and surgical intensive care unit (ICU) at an academic tertiary-care hospital. Measurements and Main Results: Measurements included the proportion for whom the ventilation tidal volume (TV) was <= 7.5 mL/kg predicted body weight (PBW) on days 2, 4, and 7 of ALI and the proportion for whom the ventilation TV was <= 6.5 and <= 8.5 mL/kg/PBW (sensitivity analysis). Demographic and clinical characteristics of patients undergoing ventilation with low and high TV were compared. Of 88 total patients studied, 39% had ventilation with TV <= 7.5 mL/kg/PBW on day 2 of ALI, 49% on day 4, and 56% on day 7. In contrast, 49% of patients had ventilation with TV >8.5 mL/kg/PBW on day 2 of ALI, 30% on day 4, and 24% on day 7. The use of low TV was significantly associated with clinical parameters indicative of worse disease severity, including low values for Pao(2) (P =.01), Pao(2)/FiO(2) (P =.08), and static compliance of the respiratory system (p =.006). Conclusions: Ventilation with a low TV was used in a minority of patients with ALI, despite results published in 1998 and 2000 supporting this approach. This may be related to clinicians' underrecognition of less severe cases of ALI, their reserving of low-TV ventilation for more severe cases, or both.
引用
收藏
页码:300 / 306
页数:7
相关论文
共 18 条
[1]  
*AC RESP DISTR SYN, 2000, NEW ENGL J MED, V342, P1301, DOI DOI 10.1056/NEJM200005043421801
[2]   Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome [J].
Amato, MBP ;
Barbas, CSV ;
Medeiros, DM ;
Magaldi, RB ;
Schettino, GDP ;
Lorenzi, G ;
Kairalla, RA ;
Deheinzelin, D ;
Munoz, C ;
Oliveira, R ;
Takagaki, TY ;
Carvalho, CRR .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (06) :347-354
[3]  
AZZAM H, 2005, AM J RESP CRIT CARE, pA432
[4]   Lung-protective ventilation strategies in acute lung injury [J].
Brower, RG ;
Rubenfeld, GD .
CRITICAL CARE MEDICINE, 2003, 31 (04) :S312-S316
[5]   Why don't physicians follow clinical practice guidelines? A framewouk for improvement [J].
Cabana, MD ;
Rand, CS ;
Powe, NR ;
Wu, AW ;
Wilson, MH ;
Abboud, PAC ;
Rubin, HR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (15) :1458-1465
[6]  
Cohen J., 1988, STAT POWER ANAL BEHA
[7]  
Feinstein AR, 1999, STAT MED, V18, P2557, DOI 10.1002/(SICI)1097-0258(19991015)18:19<2557::AID-SIM361>3.0.CO
[8]  
2-R
[9]  
Institute of Medicine (US) Committee on Quality of Health Care in America, 2001, CROSSING QUALITY CHA
[10]  
KALHAN R, 2002, CHEST, V122, pS52