Electrochemical sensor for hydroperoxides determination based on Prussian blue film modified electrode

被引:34
作者
Adhoum, Nafaa [1 ]
Monser, Lotfi [1 ]
机构
[1] Ctr Urbain Nord, Inst Natl Sci Appl & Technol, Lab Chim Analyt & Electrochim, Tunis 1080, Tunisia
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2008年 / 133卷 / 02期
关键词
edible oils; modified electrode; peroxide value; Prussian blue;
D O I
10.1016/j.snb.2008.03.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor for hydroperoxides determination was investigated. The sensor was based on the electrocatalytic reduction of hydroperoxides on Prussian blue (PB)-modified glassy carbon electrode. The modified electrode possesses a high electrocatalytic effect towards all studied peroxides with the highest effect obtained with H2O2 followed by tert-butyl hydroperoxide (TBH), cumene hydroperoxide (CH) and linoleic acid hydroperoxide (LAH). In addition, the modified electrode showed a good stability and a fast response time (<20s). The lower detection limits of H2O2, TBH, CH and LAH were found to be 10(-7) mol L-1, 2 x 10(-7) mol L-1, 3.5 x 10(-7) mol L-1 and 4 x 10(-7) mol L-1, respectively. The electrochemical sensor was then applied for amperometric determination of peroxide value (PV) in edible oil at an applied potential of 50 mV (vs. Ag/AgCl (1 M KCl)). A good linearity has been found in the range 0.02-1.0 mequiv. O-2/kg, with a detection limit (S/N = 3) of 0.001 mequiv. O-2/kg. The precision of the method (R.S.D., n=9) for within and between-days is better than 1.9% and 2.7%, respectively at 0.1 mequiv. O-2/kg. The method was successfully applied to the determination of PV in real edible oil samples with an excellent agreement with results obtained with the official standard Procedure. The proposed method is accurate, simple, cheap and could be used to control edible oil rancidity with a high sample throughputs (more than 120 samples/h). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:588 / 592
页数:5
相关论文
共 65 条
[1]   SIMULTANEOUS DETERMINATION OF HYDROPEROXIDES OF PHOSPHATIDYLCHOLINE, CHOLESTEROL ESTERS AND TRIACYLGLYCEROLS BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A POSTCOLUMN DETECTION SYSTEM [J].
AKASAKA, K ;
OHRUI, H ;
MEGURO, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 622 (02) :153-159
[2]   The role and relevance of the transfer coefficient α in the study of dissociative electron transfers:: Concepts and examples from the electroreduction of perbenzoates [J].
Antonello, S ;
Maran, F .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (41) :9668-9676
[3]  
Antonello S, 2001, ELEC SOC S, V2001, P148
[4]   Evidence for the transition between concerted and stepwise heterogeneous electron transfer bond fragmentation mechanisms [J].
Antonello, S ;
Maran, F .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (51) :12595-12600
[5]   Electrode reaction mechanisms for the reduction of tert-butyl peracetate, lauryl peroxide and dibenzoyl peroxide [J].
Baron, R ;
Darchen, A ;
Hauchard, D .
ELECTROCHIMICA ACTA, 2006, 51 (07) :1336-1341
[6]   RETRACTED: Reproducible reduction signal of organic hydroperoxides at an in situ electrodeposited iron microelectrode, due to the reconstitution of the active surface of the electrode (Retracted Article) [J].
Baron, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 576 (02) :261-267
[7]  
BUSTER HJ, 1977, INORG CHEM, V16, P2704
[8]   DETECTION OF PICOMOLE LEVELS OF HYDROPEROXIDES USING A FLUORESCENT DICHLOROFLUORESCEIN ASSAY [J].
CATHCART, R ;
SCHWIERS, E ;
AMES, BN .
ANALYTICAL BIOCHEMISTRY, 1983, 134 (01) :111-116
[9]   DETERMINATION OF LIPID HYDROPEROXIDES IN NATIVE LOW-DENSITY-LIPOPROTEIN BY A CHEMILUMINESCENT FLOW-INJECTION ASSAY [J].
COMINACINI, L ;
PASTORINO, AM ;
MCCARTHY, A ;
CAMPAGNOLA, M ;
GARBIN, U ;
DAVOLI, A ;
DESANTIS, A ;
LOCASCIO, V .
BIOCHIMICA ET BIOPHYSICA ACTA, 1993, 1165 (03) :279-287
[10]   OXIDATIVE STRESS, GLUTAMATE, AND NEURODEGENERATIVE DISORDERS [J].
COYLE, JT ;
PUTTFARCKEN, P .
SCIENCE, 1993, 262 (5134) :689-695