Large-scale μLC-MS/MS for silver- and Coomassie blue-stained polyacrylamide gels

被引:10
作者
Zhu, WH
Venable, J
Giometti, CS
Khare, T
Tollaksen, S
Ahrendt, AJ
Yates, JR
机构
[1] Scripps Res Inst, Dept Cell Biol, La Jolla, CA 92037 USA
[2] Argonne Natl Lab, Biosci Div, Argonne, IL 60439 USA
关键词
automation; Coomassie Blue staining; mu LC-MS/MS; mass spectrometry; protein identification; SEQUEST; silver staining; two-dimensional gel electrophoresis;
D O I
10.1002/elps.200500093
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
2-DE combined with LC-MS/MS has become a routine, reliable protein separation and identification technology for proteome analysis. The demand for large-scale protein identifications after 2-DE separation requires a sensitive and high-throughput LC-MS/MS method. In this report, a simple, splitless, fully automated capillary LC-MS/MS system was described for the large-scale identification of proteins from gels stained with either silver or CBB. The gel samples were digested and peptides were extracted using an in-gel digestion workstation. The peptides were automatically introduced into a capillary column by an autosampler connected to an HPLC pump. A nanoLC pump was then used to deliver the gradient and elute the peptides from the capillary column directly into an LCQ IT mass spectrometer. Neither a peptide trapping setting nor a flow split is needed in this simple setup. The collected MS/MS spectra were then automatically searched by SEQUEST, and filtered and organized by DTASelect. Hundreds of silver-stained or CBB-stained Shewanella oneidensis, Geobacter sulfurreducens, and Geobacter metallireducens proteins separated by denaturing or nondenaturing 2-DE were digested and routinely analyzed using this fully automated mu LC-MS/MS system. High peptide hits and sequence coverage were achieved for most CBB-stained gel spots. About 75% of the spots were found to contain multiple proteins. Although silver staining is not commonly thought to be optimal for MS analysis, protein identifications were successfully obtained from silver-stained 2-DE spots detected using methods with and without formaldehyde for protein fixation.
引用
收藏
页码:4495 / 4507
页数:13
相关论文
共 41 条
[1]  
ANDERSON NL, 1985, ELECTROPHORESIS, V6, P592
[2]   MECHANISM STUDIES OF COOMASSIE BLUE AND SILVER STAINING OF PROTEINS [J].
DEMORENO, MR ;
SMITH, JF ;
SMITH, RV .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1986, 75 (09) :907-911
[3]  
Devreese B, 2001, RAPID COMMUN MASS SP, V15, P50, DOI 10.1002/1097-0231(20010115)15:1<50::AID-RCM191>3.0.CO
[4]  
2-V
[5]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[6]   Protein identification at the low femtomole level from silver-stained gels using a new fritless electrospray interface for liquid chromatography microspray and nanospray mass spectrometry [J].
Gatlin, CL ;
Kleemann, GR ;
Hays, LG ;
Link, AJ ;
Yates, JR .
ANALYTICAL BIOCHEMISTRY, 1998, 263 (01) :93-101
[7]   Global analysis of a "simple" proteome:: Methanococcus jannaschii [J].
Giometti, CS ;
Reich, C ;
Tollaksen, S ;
Babnigg, G ;
Lim, HJ ;
Zhu, WH ;
Yates, J ;
Olsen, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 782 (1-2) :227-243
[8]   QUANTITATION OF HUMAN-LEUKOCYTE PROTEINS AFTER SILVER STAINING - A STUDY WITH 2-DIMENSIONAL ELECTROPHORESIS [J].
GIOMETTI, CS ;
GEMMELL, MA ;
TOLLAKSEN, SL ;
TAYLOR, J .
ELECTROPHORESIS, 1991, 12 (7-8) :536-543
[9]   Analysis of the Shewanella oneidensis proteome by two-dimensional gel electrophoresis under nondenaturing conditions [J].
Giometti, CS ;
Khare, T ;
Tollaksen, SL ;
Tsapin, A ;
Zhu, WH ;
Yates, JR ;
Nealson, KH .
PROTEOMICS, 2003, 3 (05) :777-785
[10]  
GIOMETTI CS, 1991, ADV ELECTROPHORESIS, P359