Management of severe bone loss in acetabular revision using a trabecular metal shell

被引:95
作者
Flecher, Xavier [1 ,2 ]
Sporer, Scott [3 ,4 ]
Paprosky, Wayne [3 ,4 ]
机构
[1] St Marguerite Hosp, Dept Orthoped Surg, F-13274 Marseille 09, France
[2] Univ Aix Marseille, Dept Orthoped Surg, Marseille, France
[3] Cent Dupage Hosp, Dept Orthoped Surg, Winfield, IL USA
[4] Univ Med Ctr, RUSH, Dept Orthopaed Surg, Chicago, IL USA
关键词
total hip arthroplasty; acetabular revision; bone defect; trabecular metal; results;
D O I
10.1016/j.arth.2007.08.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We investigated the early results of trabecular metal components in 23 acetabular revisions associated with major bone loss. The mean age was 58.2 years. According to Paprosky's classification, there were 17 type IIIA and 6 type IIIB acetabular defects. Eight chronic pelvic discontinuities were intraoperatively assessed. No additional plating or bone grafting was necessary. The mean postoperative modified Postel-Merle d'Aubigne score was 10.6 points (8-12 points). The mean postoperative position of the center of rotation was 26.3 mm vertically (15-47 mm). The mean inclination was 45.1 degrees (20 degrees-63 degrees). No mechanical failure occurred at a mean follow-up of 35 months (24-50 months). Trabecular metal components appear Suitable to achieve primary stability in type III acetabular defect as an alternative to bone graft and cages.
引用
收藏
页码:949 / 955
页数:7
相关论文
共 32 条
[1]
Impaction grafting for acetabular revision: Bringing back the bone [J].
Argenson, JN ;
Paratte, S ;
Flecher, X ;
Aubaniac, JM .
ORTHOPEDICS, 2004, 27 (09) :967-968
[2]
2- to 10-year follow-up study of acetabular revisions using allograft bone to repair bone defects [J].
Avci, S ;
Connors, N ;
Petty, W .
JOURNAL OF ARTHROPLASTY, 1998, 13 (01) :61-69
[3]
REVISION ARTHROPLASTY USING AN ANTI-PROTRUSIO CAGE FOR MASSIVE ACETABULAR BONE DEFICIENCY [J].
BERRY, DJ ;
MULLER, ME .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (05) :711-715
[4]
Pelvic discontinuity in revision total hip arthroplasty [J].
Berry, DJ ;
Lewallen, DG ;
Hanssen, AD ;
Cabanela, ME .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (12) :1692-1702
[5]
Berry DJ, 2004, CLIN ORTHOP RELAT R, P106
[6]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[7]
Charnley J., 1979, LOW FRICTION ARTHROP
[8]
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[9]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[10]
Revision of the acetabular component without cement after total hip arthroplasty - A concise follow-up, at fifteen to nineteen years, of a previous report [J].
Della Valle, CJ ;
Shuaipaj, T ;
Berger, RA ;
Rosenberg, AG ;
Shott, S ;
Jacobs, JJ ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) :1795-1800