Noncompetitive enzyme immunoassay for carcinoembryonic antigen by flow injection chemiluminescence

被引:64
作者
Lin, JH
Yan, F
Ju, HX [1 ]
机构
[1] Nanjing Univ, State Key Lab Coordinat Chem, Inst Analyt Sci, Dept Chem, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210009, Peoples R China
基金
中国国家自然科学基金;
关键词
flow injection analysis; chemiluminescence; noncompetitive enzyme immunoassay; immunoaffinity; carcinoembryonic antigen (CEA); horseradish peroxidase;
D O I
10.1016/j.cccn.2003.11.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Recently, many automated immunoassay analyzers have been developed for carcinoembryonic antigen (CEA) to overcome the shortcomings in traditional immunoassay methods that are time-consuming and labor-intensive. Flow injection immunoassay (FIIA) has been increasingly applied to laboratory medicine due to its ease in automation, rapid speed and reproducible results. It is important to develop a FIIA method for CEA determination. Methods: Based on a noncompetitive immunoassay format, a CEA-immobilized immunoaffinity column inserted in the flow system was used to trap the unbound horseradish peroxidase (HRP)-labeled antibody after an off-line incubation of CEA and HRP-labeled anti-CEA. The trapped enzyme conjugate was detected by injecting substrates to produce an enhanced chemiluminescence (CL). Results: The linear range for CEA was 1.0-25 ng/ml with a correlation coefficient of 0.997 and a detection limit of 0.5 ng/ml. The sampling and chemiluminescence detection time for one sample was 5 min after a preincubation procedure of 25 min. Twenty five human serum samples detected by this method were in good agreement with the results obtained by immunoradiometric assay (IRMA). Conclusions: This method could be used for rapid analysis of CEA and potentially other antigens. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 39 条
[1]  
ALUMANDA MDR, 1995, ANAL CHIM ACTA, V312, P85
[2]   Chemiluminescence-based detection:: principles and analytical applications in flowing streams and in immunoassays [J].
Baeyens, WRG ;
Schulman, SG ;
Calokerinos, AC ;
Zhao, Y ;
Campaña, AMG ;
Nakashima, K ;
De Keukeleire, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :941-953
[3]   Novel type of flow injection immunoassay for the determination of phenytoin in serum [J].
Bereczki, A ;
Horváth, V .
ANALYTICA CHIMICA ACTA, 1999, 391 (01) :9-17
[4]   Flow injection enzyme immunoassay of atrazine herbicide in water [J].
Bjarnason, B ;
Bousios, N ;
Eremin, SA ;
Johansson, G .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :111-120
[5]   Development of a heterogeneous chemiluminescent flow immunoassay for DDT and related compounds [J].
Botchkareva, AE ;
Fini, F ;
Eremin, SA ;
Mercader, JV ;
Montoya, A ;
Girotti, S .
ANALYTICA CHIMICA ACTA, 2002, 453 (01) :43-52
[6]  
Bremer K., 1995, EUR J CANCER, V31, pS262
[7]   Development of an off line noncompetitive flow immunoassay for the determination of interleukin-8 in cell samples [J].
Burestedt, E ;
Kjellström, S ;
Emnéus, J ;
Marko-Varga, G .
ANALYTICAL BIOCHEMISTRY, 2000, 279 (01) :46-54
[8]   Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125 [J].
Dai, Z ;
Yan, F ;
Chen, J ;
Ju, HX .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5429-5434
[9]  
Diaz AN, 1996, ANAL CHIM ACTA, V321, P219
[10]  
Diaz AN, 1997, J BIOLUM CHEMILUM, V12, P199, DOI 10.1002/(SICI)1099-1271(199707/08)12:4<199::AID-BIO445>3.0.CO