Output power leveling of wind turbine generator for all operating regions by pitch angle control

被引:329
作者
Senjyu, Tomonobu [1 ]
Sakamoto, Ryosei
Urasaki, Naomitsti
Funabashi, Toshihisa
Fujita, Hideki
Sekine, Hideomi
机构
[1] Univ Ryukyus, Fac Engn, Dept Elect & Elect Engn, Okinawa 9030213, Japan
[2] Meidensha Corp, Tokyo 1418565, Japan
[3] Chubu Elect Power Co Inc, Nagoya, Aichi 4598522, Japan
[4] Univ Ryukyus, Dept Educ Technol, Okinawa 9030213, Japan
关键词
generalized predictive control; output power fluctuation; pitch angle control; wind turbine generator (WTG);
D O I
10.1109/TEC.2006.874253
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wind energy is not constant and windmill output isproportional to the cube of wind speed, which causes the generated power of wind turbine generators (WTGs) to fluctuate. In order to reduce fluctuation, different methods are available to control the pitch angle of blades of windmill. In a previous work, we proposed the pitch angle, control using minimum variance control, and output power leveling was achieved. However, it is a controlled output power for only rated wind speed region. This paper presents a control strategy based on average wind speed and standard deviation of wind speed and pitch angle control using a generalized predictive control in all operating regions for a WTG. The simulation results by using actual detailed model for wind power system show the effectiveness of the proposed method.
引用
收藏
页码:467 / 475
页数:9
相关论文
共 18 条
[1]   Power fluctuations in an isolated wind plant [J].
Carrillo, C ;
Feijóo, AE ;
Cidrás, J ;
González, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (01) :217-221
[2]   Synchronization of asynchronous wind turbines [J].
Cidrás, J ;
Feijóo, AE ;
González, CC .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (04) :1162-1169
[3]  
CLARK D, 1987, J CAN DENT ASSOC, V2, P137
[4]   GENERALIZED PREDICTIVE CONTROL .2. EXTENSIONS AND INTERPRETATIONS [J].
CLARKE, DW ;
MOHTADI, C ;
TUFFS, PS .
AUTOMATICA, 1987, 23 (02) :149-160
[5]   SELF-TUNING CONTROL OF NONMINIMUM-PHASE SYSTEMS [J].
CLARKE, DW .
AUTOMATICA, 1984, 20 (05) :501-517
[6]   SELF-TUNING CONTROLLER [J].
CLARKE, DW ;
GAWTHROP, PJ .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1975, 122 (09) :929-934
[7]  
Kanna O., 1997, Transactions of the Institute of Electrical Engineers of Japan, Part B, V117-B, P1513
[8]  
Kodama N., 2000, Transactions of the Institute of Electrical Engineers of Japan, Part B, V120-B, P210
[9]   Doubly fed induction generator model for transient stability analysis [J].
Ledesma, P ;
Usaola, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :388-397
[10]  
Matsuzaka T., 1997, Transactions of the Institute of Electrical Engineers of Japan, Part B, V117-B, P625