OBJECTIVES The aim of our study was to evaluate the feasibility, the safety, and hemodynamic improvements induced by permanent para-Hisian pacing in patients with chronic atrial fibrillation and narrow QRS who underwent atrioventricular (AV) node ablation. BACKGROUND Right ventricular apical pacing, inducing asynchronous ventricular contraction, may impair cardiac function; permanent para-Hisian pacing could preserve interventricular synchrony and improve left ventricular function. METHODS After AV node ablation, 16 patients were implanted with a dual-chamber pacemaker connected to a screw-in lead positioned in close proximity to the His bundle and to a right ventricular apical lead. Clinical and echocardiographic data were collected at baseline and after two randomized six-month periods (with para-Hisian and conventional pacing). RESULTS During para-Hisian pacing, the interventricular electromechanical delay improved as well (34 +/- 18 ms) as during right apical pacing (47 +/- 19 ms), p < 0.05. Para-Hisian pacing allowed an improvement in New York Heart Association functional class (1.75 +/- 0.4 vs. 2.33 +/- 0.6 at baseline and 2.5 +/- 0.4 during apical pacing, p < 0.05 for both), in quality-of-life score (16.2 +/- 8.7 vs. 32.5 +/- 15.0 at baseline, p < 0.05), and in the 6-min walk test (431 73 m vs. 378 60 in at baseline and 360 +/- 71 in during apical pacing, p < 0.5 for both). Mitral and tricuspid regurgitation improved during para-Hisian pacing (1.22 +/- 0.8 and 1.46 +/- 0.5 index, respectively, vs. 1.68 +/- 0.6 [p < 0.05] and 1.62 +/- 0.7 [p = NS] index at baseline, respectively), with a slight worsening during apical pacing (1.93 +/- 1 and 1.93 +/- 0.7 index, respectively, p < 0.05 for both). CONCLUSIONS Permanent para-Hisian pacing is feasible and safe. Compared with conventional right apical pacing, it allows an improvement in functional and hemodynamic parameters over long-term follow-up. (J Am Coll Cardiol 2006;47:1938-45) (c) 2006 by the American College of Cardiology Foundation.
引用
收藏
页码:1938 / 1945
页数:8
相关论文
共 34 条
  • [1] Abraham WT, 2002, NEW ENGL J MED, V346, P1902
  • [2] Experimental His-bundle pacing: Histopathological and electrophysiological examination
    Amitani, S
    Miyahara, K
    Sohara, H
    Kakura, H
    Koga, M
    Moriyama, Y
    Taira, A
    Nagano, S
    Miura, N
    Misumi, K
    Sakamoto, H
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (04): : 562 - 566
  • [3] Adverse effects of ventricular desynchronization induced by long-term right ventricular pacing
    Barold, SS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (04) : 624 - 626
  • [4] Assessment of atrioventricular junction ablation and DDDR mode-switching pacemaker versus pharmacological treatment in patients with severely symptomatic paroxysmal atrial fibrillation - A randomized controlled study
    Brignole, M
    Gianfranchi, L
    Menozzi, C
    Alboni, P
    Musso, G
    Bongiorni, MG
    Gasparini, M
    Raviele, A
    Lolli, G
    Paparella, N
    Acquarone, S
    [J]. CIRCULATION, 1997, 96 (08) : 2617 - 2624
  • [5] Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    Bristow, MR
    Saxon, LA
    Boehmer, J
    Krueger, S
    Kass, DA
    De Marco, T
    Carson, P
    DiCarlo, L
    DeMets, D
    White, BG
    DeVries, DW
    Feldman, AM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) : 2140 - 2150
  • [6] The effect of cardiac resynchronization on morbidity and mortality in heart failure
    Cleland, JGF
    Daubert, J
    Erdmann, E
    Freemantle, N
    Gras, D
    Kappenberger, L
    Tavazzi, L
    Cleland, JGF
    Daubert, JC
    Erdmann, E
    Gras, D
    Kappenberger, L
    Klein, W
    Tavazzi, L
    Poole-Wilson, PA
    Rydén, L
    Wedel, H
    Wellens, HJJ
    Uretsky, B
    Thygesen, K
    Böcker, D
    Marijianowski, MMH
    Freemantle, N
    Calvert, MJ
    Christ, G
    Fruhwald, F
    Hofmann, R
    Krypta, A
    Leisch, F
    Pacher, R
    Rauscha, F
    Tavernier, R
    Thomsen, PEB
    Boesgaard, S
    Eiskjær, H
    Esperen, GT
    Haarbo, J
    Hagemann, A
    Korup, E
    Moller, M
    Mortensen, P
    Sogaard, P
    Vesterlund, T
    Huikuri, H
    Niemelä, KI
    Toivonen, L
    Bauer, F
    Cohen-Solal, A
    Crocq, C
    Djiane, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) : 1539 - 1549
  • [7] Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes
    Connolly, SJ
    Kerr, CR
    Gent, M
    Roberts, RS
    Yusuf, S
    Gillis, AM
    Sami, MH
    Talajic, M
    Tang, ASL
    Klein, GJ
    Lau, C
    Newman, DM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (19) : 1385 - 1391
  • [8] Comparison of the haemodynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing - A quantitative review
    de Cock, CC
    Giudici, MC
    Twisk, JV
    [J]. EUROPACE, 2003, 5 (03): : 275 - 278
  • [9] Permanent, direct his-bundle pacing - A novel approach to cardiac pacing in patients with normal His-purkinje activation
    Deshmukh, P
    Casavant, DA
    Romanyshyn, M
    Anderson, K
    [J]. CIRCULATION, 2000, 101 (08) : 869 - 877
  • [10] Direct his-bundle pacing: Present and future
    Deshmukh, PM
    Romanyshyn, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06): : 862 - 870