Finite element modeling of embolic coil deployment: Multifactor characterization of treatment effects on cerebral aneurysm hemodynamics

被引:58
作者
Babiker, M. Haithem [1 ]
Chong, Brian [2 ]
Gonzalez, L. Fernando [3 ]
Cheema, Sachmanik [4 ]
Frakes, David H. [1 ,4 ]
机构
[1] Arizona State Univ, Sch Biol & Hlth Syst Engn, Tempe, AZ 85287 USA
[2] Mayo Clin Hosp, Phoenix, AZ USA
[3] Thomas Jefferson Univ, Jefferson Med Coll, Dept Neurol Surg, Philadelphia, PA 19107 USA
[4] Arizona State Univ, Sch Elect Comp & Energy Engn, Tempe, AZ 85287 USA
基金
美国国家科学基金会;
关键词
Computational fluid dynamics; Finite element model; Embolic coil; Cerebral aneurysm; Packing density; GUGLIELMI DETACHABLE COILS; SELECTIVE ENDOVASCULAR TREATMENT; INTRACRANIAL ANEURYSMS; PACKING DENSITY; CONFIGURATION; EMBOLIZATION; FLOW;
D O I
10.1016/j.jbiomech.2013.08.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Endovascular coiling is the most common treatment for cerebral aneurysms. During the treatment, a sequence of embolic coils with different stiffness, shapes, sizes, and lengths is deployed to fill the aneurysmal sac. Although coil packing density has been clinically correlated with treatment success, many studies have also reported success at low packing densities, as well as recurrence at high packing densities. Such reports indicate that other factors may influence treatment success. In this study, we used a novel finite element approach and computational fluid dynamics (CFD) to investigate the effects of packing density, coil shape, aneurysmal neck size, and parent vessel flow rate on aneurysmal hemodynamics. The study examines a testbed of 80 unique CFD simulations of post-treatment flows in idealized basilar tip aneurysm models. Simulated coil deployments were validated against in vitro and in vivo deployments. Among the investigated factors, packing density had the largest effect on intraaneurysmal velocities. However, multifactor analysis of variance showed that coil shape can also have considerable effects, depending on packing density and neck size. Further, linear regression analysis showed an inverse relationship between mean void diameter in the aneurysm and mean intraaneurysmal velocities, which underscores the importance of coil distribution and thus coil shape. Our study suggests that while packing density plays a key role in determining post-treatment hemodynamics, other factors such as coil shape, aneurysmal geometry, and parent vessel flow may also be very important. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2809 / 2816
页数:8
相关论文
共 24 条
[1]
[Anonymous], 2006, Planning algorithms
[2]
Influence of stent configuration on cerebral aneurysm fluid dynamics [J].
Babiker, M. Haithem ;
Gonzalez, L. Fernando ;
Ryan, Justin ;
Albuquerque, Felipe ;
Collins, Daniel ;
Elvikis, Arius ;
Frakes, David H. .
JOURNAL OF BIOMECHANICS, 2012, 45 (03) :440-447
[3]
Quantitative Effects of Coil Packing Density on Cerebral Aneurysm Fluid Dynamics: An In Vitro Steady Flow Study [J].
Babiker, M. Haithem ;
Gonzalez, L. Fernando ;
Albuquerque, Felipe ;
Collins, Daniel ;
Elvikis, Arius ;
Frakes, David H. .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (07) :2293-2301
[4]
Guidelines for the Management of Aneurysmal Subarachnoid Hemorrhage A Statement for Healthcare Professionals From a Special Writing Group of the Stroke Council, American Heart Association [J].
Bederson, Joshua B. ;
Connolly, E. Sander, Jr. ;
Batjer, H. Hunt ;
Dacey, Ralph G. ;
Dion, Jacques E. ;
Diringer, Michael N. ;
Duldner, John E., Jr. ;
Harbaugh, Robert E. ;
Patel, Aman B. ;
Rosenwasser, Robert H. .
STROKE, 2009, 40 (03) :994-1025
[5]
Difficult Aneurysms for Endovascular Treatment: Overwide or Undertall? [J].
Brinjikji, W. ;
Cloft, H. J. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (08) :1513-1517
[6]
Medical progress: Cerebral aneurysms [J].
Brisman, Jonathan L. ;
Song, Joon K. ;
Newell, David W. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (09) :928-939
[7]
CFD modeling of blood flow following coil embolization of aneurysms [J].
Byun, HS ;
Rhee, K .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (09) :755-761
[8]
Dequidt J, 2009, LECT NOTES COMPUT SC, V5761, P377, DOI 10.1007/978-3-642-04268-3_47
[9]
Dorf RC., 2004, CRC Handbook of Engineering Tables
[10]
Selective use of electrolytic detachable and fibered coils to embolize a wide-neck giant splenic artery pseudoaneurysm [J].
Hung, RK ;
Loh, C ;
Goldstein, L .
JOURNAL OF VASCULAR SURGERY, 2005, 41 (05) :889-892