Pulmonary perfusion is more uniform in the prone than in the supine position:: scintigraphy in healthy humans

被引:102
作者
Nyrén, S
Mure, M [1 ]
Jacobsson, H
Larsson, SA
Lindahl, SGE
机构
[1] Karolinska Hosp & Inst, Dept Anesthesia & Intens Care, S-17176 Stockholm, Sweden
[2] Karolinska Hosp & Inst, Dept Diagnost Radiol, S-17176 Stockholm, Sweden
[3] Karolinska Hosp & Inst, Dept Hosp Phys, S-17176 Stockholm, Sweden
关键词
continuous positive airway pressure; gravity dependence; human volunteers; lung perfusion; prone position; single-photon-emission computed tomography; supine position;
D O I
10.1152/jappl.1999.86.4.1135
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The main purpose of this study was to find out whether the dominant dorsal lung perfusion while supine changes to a dominant ventral lung perfusion while prone. Regional distribution of pulmonary blood flow was determined in 10 healthy volunteers. The subjects were studied in both prone and supine positions with and without lung distension caused by 10 cmH(2)O of continuous positive airway pressure (CPAP). Radiolabeled macroaggregates of albumin, rapidly trapped by pulmonary capillaries in proportion to blood flow, were injected intravenously. Tomographic gamma camera examinations (single-photon-emission computed tomography) were performed after injections in the different positions. All data acquisitions were made with the subject in the supine position. CPAP enhanced perfusion differences along the gravitational axis, which was more pronounced in the supine than prone position. Diaphragmatic sections of the lung had a more uniform pulmonary blood flow distribution in the prone than supine position during both normal and CPAP breathing. It was concluded that the dominant dorsal lung perfusion observed when the subjects were supine was not changed into a dominant ventral lung perfusion when the subjects were prone. Lung perfusion was more uniformly distributed in the prone compared with in the supine position, a difference that was more marked during total lung distension (CPAP) than during normal breathing.
引用
收藏
页码:1135 / 1141
页数:7
相关论文
共 29 条
[1]  
ALBERT RK, 1987, AM REV RESPIR DIS, V135, P628
[2]   EFFECT OF POSTURE ON INTER-REGIONAL DISTRIBUTION OF PULMONARY PERFUSION AND VA/Q RATIOS IN MAN [J].
AMIS, TC ;
JONES, HA ;
HUGHES, JMB .
RESPIRATION PHYSIOLOGY, 1984, 56 (02) :169-182
[3]   REGIONAL PULMONARY FUNCTION STUDIED WITH XENON133 [J].
BALL, WC ;
NEWSHAM, LGS ;
STEWART, PB ;
BATES, DV .
JOURNAL OF CLINICAL INVESTIGATION, 1962, 41 (03) :519-&
[4]   DIFFERENCES IN REGIONAL VASCULAR CONDUCTANCES IN ISOLATED DOG LUNGS [J].
BECK, KC ;
REHDER, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (02) :530-538
[5]   FACTORS AFFECTING REGIONAL DISTRIBUTION OF VENTILATION + PERFUSION IN LUNG [J].
BRYAN, AC ;
MACLEISH, H ;
BENTIVOGLIO, LG ;
BEEREL, F ;
BATES, DV ;
ZIDULKA, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (03) :395-+
[6]  
DOUGLAS WW, 1977, AM REV RESPIR DIS, V115, P559
[7]  
Glenny R. W., 1997, FASEB Journal, V11, pA344
[8]   FRACTAL PROPERTIES OF PULMONARY BLOOD-FLOW - CHARACTERIZATION OF SPATIAL HETEROGENEITY [J].
GLENNY, RW ;
ROBERTSON, HT .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (02) :532-545
[9]   GRAVITY IS A MINOR DETERMINANT OF PULMONARY BLOOD-FLOW DISTRIBUTION [J].
GLENNY, RW ;
LAMM, WJE ;
ALBERT, RK ;
ROBERTSON, HT .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (02) :620-629
[10]   GRAVITY-INDEPENDENT INEQUALITY IN PULMONARY BLOOD-FLOW IN HUMANS [J].
HAKIM, TS ;
LISBONA, R ;
DEAN, GW .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (03) :1114-1121