Jugular venous bulb oxyhemoglobin saturation during cardiac surgery: Accuracy and reliability using a continuous monitor

被引:19
作者
Trubiano, P
Heyer, EJ
Adams, DC
McMahon, DJ
Christiansen, I
Rose, EA
Delphin, E
机构
[1] COLUMBIA UNIV,DEPT ANESTHESIOL,NEW YORK,NY 10032
[2] COLUMBIA UNIV,DEPT NEUROL,NEW YORK,NY 10032
[3] COLUMBIA UNIV,DEPT SURG,DIV CARDIOTHORAC,NEW YORK,NY 10032
[4] COLUMBIA UNIV,IRVING CTR CLIN RES,NEW YORK,NY 10032
关键词
D O I
10.1097/00000539-199605000-00013
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Previous studies have demonstrated the feasibility of continuously monitoring jugular venous oxygen saturation (Sjo(2)) with a fiberoptic catheter during hypothermic cardiopulmonary bypass (CPB). In the present study, with patients maintained at either moderate (28 degrees C) or mild (32-34 degrees C) hypothermia during CPB, Sjo(2) values obtained from a fiberoptic catheter were compared to intermittent samples analyzed by a co-oximeter. Twenty patients scheduled for elective coronary artery or valvular surgery had a 5.5 Fr Opticath catheter inserted into the left internal jugular bulb after induction of general anesthesia. The catheter was calibrated in vitro and in vivo according to the manufacturer's specifications. Catheter and co-oximetry Sjo(2) values obtained at four time points-1) pre-CPB, 2) target CPB temperature, 3) mid-rewarming, and 4) post-CPB-were compared using linear regression, Bland-Altman analysis, and Shrout-Fleiss interclass correlation coefficient analysis. These statistical methods revealed poor correlation between the catheter and co-oximetry Sjo(2) values: r = 0.44 by linear regression and 0.32 by interclass correlation coefficient analysis, and was unacceptably discrepant by Bland-Altman analysis. Oxyhemoglobin saturation values obtained continuously from a jugular venous bulb fiberoptic catheter during CPB may not accurately reflect true oxyhemoglobin saturation, and caution is warranted when interpreting Sjo(2) values obtained from a fiberoptic catheter during CPB.
引用
收藏
页码:964 / 968
页数:5
相关论文
共 23 条
[1]   JUGULAR BULB CANNULATION - DESCRIPTION OF A CANNULATION TECHNIQUE AND VALIDATION OF A NEW CONTINUOUS MONITOR [J].
ANDREWS, PJD ;
DEARDEN, NM ;
MILLER, JD .
BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (05) :553-558
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   A PROSPECTIVE, RANDOMIZED COMPARISON OF CEREBRAL VENOUS OXYGEN-SATURATION DURING NORMOTHERMIC AND HYPOTHERMIC CARDIOPULMONARY BYPASS [J].
COOK, DJ ;
OLIVER, WC ;
ORSZULAK, TA ;
DALY, RC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (04) :1020-1029
[4]   WARMING DURING CARDIOPULMONARY BYPASS IS ASSOCIATED WITH JUGULAR BULB DESATURATION [J].
CROUGHWELL, ND ;
FRASCO, P ;
BLUMENTHAL, JA ;
LEONE, BJ ;
WHITE, WD ;
REVES, JG .
ANNALS OF THORACIC SURGERY, 1992, 53 (05) :827-832
[5]   THEORETICAL-ANALYSIS OF CEREBRAL VENOUS-BLOOD HEMOGLOBIN OXYGEN-SATURATION AS AN INDEX OF CEREBRAL OXYGENATION DURING HYPOTHERMIC CARDIOPULMONARY BYPASS - A COUNTERPROPOSAL TO THE LUXURY PERFUSION HYPOTHESIS [J].
DEXTER, F ;
HINDMAN, BJ .
ANESTHESIOLOGY, 1995, 83 (02) :405-412
[6]  
FURLAN AJ, 1992, NEUROL CLIN, V10, P145
[7]  
GRAVLEE GP, 1984, J THORAC CARDIOV SUR, V88, P742
[8]   INTRAOPERATIVE DATA-ACQUISITION FOR THE STUDY OF CEREBRAL-DYSFUNCTION FOLLOWING CARDIOPULMONARY BYPASS [J].
HEYER, EJ ;
WALD, A ;
MENCKE, A .
JOURNAL OF CLINICAL MONITORING, 1995, 11 (05) :305-310
[9]  
JOURNOIS D, 1994, ANESTH ANALG, V79, P1017
[10]   VALIDITY OF INTERNAL JUGULAR BLOOD FOR STUDY OF CEREBRAL BLOOD FLOW AND METABOLISM [J].
LASSEN, NA ;
LANE, MH .
JOURNAL OF APPLIED PHYSIOLOGY, 1961, 16 (02) :313-&