Surface EMG analysis on normal subjects based on isometric voluntary contraction

被引:52
作者
Kaplanis, P. A. [1 ,4 ]
Pattichis, C. S. [2 ]
Hadjileontiadis, L. J. [3 ]
Roberts, V. C. [4 ]
机构
[1] Cyprus Inst Neurol & Genet, Dept Comp Intelligence, CY-1683 Nicosia, Cyprus
[2] Univ Cyprus, Dept Comp Sci, Nicosia, Cyprus
[3] Aristotle Univ Thessaloniki, Dept Elect & Comp Engn, GR-54006 Thessaloniki, Greece
[4] Univ London, Univ London Kings Coll, Sch Med & Dent, London SW3 6LX, England
基金
新加坡国家研究基金会;
关键词
SEMG; Time domain analysis; Power spectrum analysis; Bispectrum analysis; POWER SPECTRUM; ELECTROMYOGRAPHIC SIGNAL; MYOELECTRIC SIGNAL; INCREASING FORCE; MUSCLE; LEVEL; REPEATABILITY; PARAMETERS; FREQUENCY; VARIABLES;
D O I
10.1016/j.jelekin.2007.03.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The objective of this study was to compute reference SEMG values for normal subjects of 13 parameters extracted in the time, frequency and bispectrum domain, from the Biceps Brachii (BB) muscle generated under isometric voluntary contraction (IVC). SEMG signals were recorded from 94 subjects for 5 s at 10, 30, 50, 70 and 100% of maximum voluntary contraction (MVC). The Wilcoxon signed rank test was applied to detect significant differences or not at p < 0.05 between force levels for each of the 13 parameters. The main findings of this study can be summarized as follows: (i) The time domain parameters turns per second and number of zero crossings per second increase significantly with force level. (ii) The power spectrum median frequency parameter decreases significantly with force level, whereas maximum power and total power increase significantly with force level. (iii) The bispectrum parameter, maximum amplitude. increases significantly with force level with the exception the transition from 30% to 50% MVC. Although, the tests for Gaussianity and linearity show no significant difference with force level, the SEMG signal exhibits it more Gaussian distribution with increase of force up to 70% MVC. The SEMG linearity test, which is a measure of how constant the bicoherence index is in the bi-frequency domain, shows that the signal's bicoherence index is less constant (hence, the signal is less linear) at 70% of MVC compared to 10. 30, 50 and 100%, MVC. (iv) The time domain parameters have good correlation between them as well as, between each one of them and maximum and total power. The median frequency has a good (negative) correlation with the bispectrum peak amplitude. (v) No significant differences exist between values based on gender or age. The findings of this study can further be used for the assessment of subjects suffering with neuromuscular disorders, or in the rehabilitation laboratory for monitoring the elderly or the disabled, or in the occupational medicine laboratory. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 171
页数:15
相关论文
共 39 条
[1]  
[Anonymous], 1985, Muscle alive: their functions revealed by electromyography
[2]   CHANGES IN THE ELECTROMYOGRAPHIC SPECTRUM POWER DISTRIBUTION CAUSED BY A PROGRESSIVE INCREASE IN THE FORCE LEVEL [J].
BILODEAU, M ;
CINCERA, M ;
GERVAIS, S ;
ARSENAULT, AB ;
GRAVEL, D ;
LEPAGE, Y ;
MCKINLEY, P .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 71 (2-3) :113-123
[3]   INFLUENCE OF GENDER ON THE EMG POWER SPECTRUM DURING AN INCREASING FORCE LEVEL [J].
BILODEAU, M ;
ARSENAULT, AB ;
GRAVEL, D ;
BOURBONNAIS, D .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1992, 2 (03) :121-129
[4]  
CHAFFIN DB, 1969, J OCCUP MED, V11
[5]  
*DELSYS INC, 1996, SURF EL DET REC
[6]   Motor unit recruitment strategies investigated by surface EMG variables [J].
Farina, D ;
Fosci, M ;
Merletti, R .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (01) :235-247
[7]   INTEGRATED ELECTRICAL-ACTIVITY AND NUMBER OF ZERO CROSSINGS DURING A GRADUAL INCREASE IN MUSCLE FORCE IN PATIENTS WITH NEUROMUSCULAR DISEASES [J].
FUGLSANGFREDERIKSEN, A ;
LOMONACO, M ;
DAHL, K .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 58 (03) :211-219
[8]  
GANDER RE, 1985, ELECTROMYOGRAPHY CLI, V25, P169
[9]  
GERDLE B, 1990, Electromyography and Clinical Neurophysiology, V30, P483
[10]  
GROSSMAN WI, 1966, PHYCHOSOM MED, V28, P53