Highly sensitive electrogenerated chemiluminescence (ECL) method for famotidine with pre-anodizing technique to improve ECL reaction microenvironment at graphite electrode surface

被引:13
作者
Chang, Z [1 ]
Zheng, XW [1 ]
机构
[1] Shaanxi Normal Univ, Coll Chem & Mat Sci, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
electrogenerated chemiluminescence; the pre-anodized graphite electrode; chemically modified electrode; ECL reaction microenvironment;
D O I
10.1016/j.jelechem.2005.11.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, it was found that, compared to the modification of the graphite electrode with carboxyl-based multi-walled carbon nanotubes, the pre-anodized graphite electrode prepared by electrochemical method, not only still owned the pre-concentrating effect for famotidine, but also created a suitable electrogenerated chemiluminescence (ECL) reaction microenvironment to improve the enhancing ECL effect of the famotidine on electro-oxidation of Ru(bpy)(3)(2+). Based on these findings, a new ECL method for famotidine was developed. Under the optimum experimental conditions, this new ECL method offered a 1.9 x 10(-10) g/mL detection limit for famotidine and the enhancing ECL signal was linear with famotidine concentration in the range of 1.0 x 10(-9) -1.0 x 10(-6) g/mL. The presented method was successfully used to detect famotidine in plasma samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 27 条
[1]   Study of the electrochemiluminescence based on tris(2,2′-bipyridine) ruthenium(II) and alcohols in a flow injection system [J].
Chen, X ;
Sato, M ;
Lin, YJ .
MICROCHEMICAL JOURNAL, 1998, 58 (01) :13-20
[2]   ELECTROCHEMICAL PRETREATMENT OF GLASSY-CARBON ELECTRODES [J].
ENGSTROM, RC .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2310-2314
[3]   Analytical applications of tris(2,2′-bipyridyl)ruthenium(III) as a chemiluminescent reagent [J].
Gerardi, RD ;
Barnett, NW ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :1-41
[4]   Electrochemical behavior and simultaneous determination of vitamin B2, B6, and C at electrochemically pretreated glassy carbon electrode [J].
Gu, HY ;
Yu, AM ;
Chen, HY .
ANALYTICAL LETTERS, 2001, 34 (13) :2361-2374
[5]   Electrogenerated chemiluminescence of the ruthenium Tris(2,2')bipyridyl/amines system on a boron-doped diamond electrode [J].
Honda, K ;
Yoshimura, M ;
Rao, TN ;
Fujishima, A .
JOURNAL OF PHYSICAL CHEMISTRY B, 2003, 107 (07) :1653-1663
[6]   A review of recent trends in analytical applications of electrogenerated chemiluminescence [J].
Knight, AW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (01) :47-62
[7]   OCCURRENCE, MECHANISMS AND ANALYTICAL APPLICATIONS OF ELECTROGENERATED CHEMILUMINESCENCE - REVIEW [J].
KNIGHT, AW ;
GREENWAY, GM .
ANALYST, 1994, 119 (05) :879-890
[8]   Tris (2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence in analytical science [J].
Lee, WY .
MIKROCHIMICA ACTA, 1997, 127 (1-2) :19-39
[9]  
Li B, 2000, CHEM J CHINESE U, V21, P1633
[10]   Monitoring costs and the mode of international investment [J].
Lin, CCS ;
Png, I .
JOURNAL OF ECONOMIC GEOGRAPHY, 2003, 3 (03) :261-274